IPeer.Receive2 (METH)ΒΆ
METHOD Receive2 : ERROR
This method serves to receive data.
The pointer
pData specifies the memory area
to write the read data to. udiSize defines the max number of bytes to read. When data was read
successfully, udiCount indicates the actually read number of bytes.itfIPAddressFrom and uiPortFrom indicate the ip and port the data was received from.See: TRANSMISSION
Below is an example of how to handle the itfIPAddressFrom parameter.
It is necessary to assign an instance of NBS.IPv4Address to a variable of type NBS.IIPAddress.
VAR
eErrorID : NBS.ERROR;
myPeer : NBS.UDP_Peer;
abyBuffer : ARRAY[0..1023] OF BYTE;
myIPAddressFrom : NBS.IPv4Address;
itfIPAddressFrom : NBS.IIPAddress := myIPAddressFrom;
uiPortFrom : UINT;
udiCount : UDINT;
eTransmission : NBS.TRANSMISSION;
myIPFrom : ARRAY[0..3] OF BYTE;
END_VAR
eErrorID := myPeer.Receive(
ADR(abyBuffer), SIZEOF(abyBuffer),
itfIPAddressFrom:=itfIPAddressFrom, uiPortFrom=>uiPortFrom,
udiCount=>udiCount,
eTransmission=>eTransmission
);
IF eErrorID = NBS.ERROR.NO_ERROR THEN
myIPFrom := myIPAddressFrom.GetIPasByteArray(eError=>eErrorID);
END_IF
- InOut:
Scope
Name
Type
Return
Receive2Input
pData__XWORDudiSizeUDINTInout
itfIPAddressFromOutput
uiPortFromUINTudiCountUDINTeTransmission