Error (ENUM)¶
TYPE Error :
Error type used in MODBUS function block library.
- Attributes:
- qualified_only
- InOut:
- Name - Initial - Comment - OK - 0 - LicenseMissing - 1 - Valid MODBUS license is missing. - InvalidDataModel - 2 - The “data model” contains errors or inconsistencies. - IllegalFunction - 3 - Undefined “function code” used to enable/disable supported “function codes”. - InvalidUnitId - 4 - Invalid Unit-Id / Slave address. - NoMemory - 21 - Can not allocate memory. - InternalError - 22 - Other internal error. - RequestNotProcessed - 50 - Request not processed in time - RequestException - 51 - Request caused reply “exception”. - RequestParameterError - 52 - Invalid request parameter, for example “Read Coils” -> “Quantity of coils” = 0 - RequestError - 53 - Internal request error - RequestCancelled - 54 - Request cancelled - ReplyError - 55 - Internal reply error - ReplyTimeout - 56 - No reply received in time - InvalidReply - 57 - Invalid / incomplete reply - TcpSocketError - 101 - Error on open/close/read/write TCP socket. - TcpInvalidInterface - 102 - The application tried to use an unknown ETH interface. - TcpConnectTimeout - 103 - TCP connect timeout. - SerialInvalidComPort - 201 - The application tried to use an unknown SysCom port. - SerialComPortUserInconsistentPortSetting - 202 - Multiple ServerSerial function blocks tried to share one SysCom port with inconsistent settings. - SerialComPortUserClientExclusiveError - 203 - A ClientSerial function block is not allowed to share a SysCom port with any other user. - SerialComPortError - 204 - Error on open/close/read/write SysCom port. - SerialInternalError - 205 - Internal error working with SysCom port. 