FindFirstValueByKey (FB)ΒΆ
FUNCTION_BLOCK FindFirstValueByKey EXTENDS CBM.ETrig
Finds the corresponding value of a key.
- InOut:
- Scope - Name - Type - Comment - Inherited from - Input - xExecute- BOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (- xDone,- xError) are present at the outputs for exactly one cycle.- ETrig - Output - xDone- BOOL- TRUE: Action successfully completed- ETrig - xBusy- BOOL- TRUE: Function block active- ETrig - xError- BOOL- TRUE: Error occurred, function block aborts action- FALSE: No error- ETrig - Input - wsKey- WSTRING- The key to search - diStartIndex- DINT- Start index - Inout - jsonData- JSONData object - Output - jsonElement- The corresponding value of the key - eError