Library Reference

This is a dictionary of all referenced libraries and their name spaces.

3SLicense

Library Identification

Placeholder: 3SLicense
Default Resolution: 3SLicense, * (3S - Smart Software Solutions GmbH)
Namespace: _3S_LICENSE

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: 3SLicense

CAA Device Diagnosis

Library Identification

Placeholder: CAA Device Diagnosis
Default Resolution: CAA Device Diagnosis, * (CAA Technical Workgroup)
Namespace: DED

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CAA Device Diagnosis

CAA Types Extern

Library Identification

Placeholder: CAA Types
Default Resolution: CAA Types Extern, * (CAA Technical Workgroup)
Namespace: CAA

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CAA Types

CmpErrors2 Interfaces

Library Identification

Name: CmpErrors2 Interfaces
Version: newest
Company: System
Namespace: CmpErrors

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpErrors2 Interfaces, * (System)

CmpEventMgr

Library Identification

Placeholder: CmpEventMgr
Default Resolution: CmpEventMgr, * (System)
Namespace: CmpEventMgr

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpEventMgr

CmpLog

Library Identification

Placeholder: CmpLog
Default Resolution: CmpLog, * (System)
Namespace: CmpLog

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpLog

CmpSettings

Library Identification

Placeholder: CmpSettings
Default Resolution: CmpSettings, * (System)
Namespace: CmpSettings

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpSettings

CommFB

Library Identification

Placeholder: CommFB
Default Resolution: CommFB, * (3S - Smart Software Solutions GmbH)
Namespace: CommFB

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CommFB

Component Manager

Library Identification

Placeholder: Component Manager
Default Resolution: Component Manager, * (System)
Namespace: Component_Manager

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Component Manager

IoDriver Interfaces

Library Identification

Name: IoDriver Interfaces
Version: newest
Company: System
Namespace: IIoDrv

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: IoDriver Interfaces, * (System)

IoDriver Parameter Interfaces

Library Identification

Name: IoDriver Parameter Interfaces
Version: newest
Company: System
Namespace: IIoDrvParameter

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: IoDriver Parameter Interfaces, * (System)

IoDrvBase

Library Identification

Placeholder: IoDrvBase
Default Resolution: IoDrvBase, * (System)
Namespace: IoDrvBase

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: IoDrvBase

IoDrvEthernet Interfaces

Library Identification

Name: IoDrvEthernet Interfaces
Version: newest
Company: 3S - Smart Software Solutions GmbH
Namespace: IIoDrvEthernet

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: IoDrvEthernet Interfaces, * (3S - Smart Software Solutions GmbH)

IoDrvProfinetBase

Library Identification

Placeholder: IoDrvProfinetBase
Default Resolution: IoDrvProfinetBase, * (3S - Smart Software Solutions GmbH)
Namespace: IoDrvProfinetBase

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: IoDrvProfinetBase

Library Parameter

Parameter: MAX_SCAN_DATA = 4096

IoStandard

Library Identification

Placeholder: IoStandard
Default Resolution: IoStandard, * (System)
Namespace: IoStandard

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: IoStandard

Profinet

Library Identification

Placeholder: Profinet
Default Resolution: Profinet, * (3S - Smart Software Solutions GmbH)
Namespace: Profinet

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: Profinet

Library Parameter

Parameter: CMPID_PROFINET = 16#10A2
Parameter: CMPID_PROFINETDEVICE = 16#1017
Parameter: MAXALARMDATALENGTH = 200
Parameter: MAXALARMPAYLOADLENGTH = (MaxAlarmDataLength - 26)
Parameter: MAXEXPDATABUFFERSIZE = (16 * 1024)
Parameter: MAXNUMFORWARDEDIPPACKETS = 32
Parameter: MAX_ADAPTER_INFO = 8
Parameter: MAX_ETHERNET_BUFFER = 64
Parameter: MAX_PARALLEL_CONNECT = 6
Parameter: MAX_PORTS = 8
Parameter: MAX_RECORD_DATA = 8192
Parameter: MAX_SCAN_BUFFER_SIZE = (1024 * 10)
Parameter: MAX_SCAN_SLAVES = 64
Parameter: MAX_SLAVES = 64
Parameter: REMOTEAPPLICATIONREADYTIMEOUT = TIME#5m0s0ms
Parameter: RTARETRIES = 3
Parameter: RTATIMEOUTFACTOR = 10

ProfinetCommon

Library Identification

Placeholder: ProfinetCommon
Default Resolution: ProfinetCommon, * (3S - Smart Software Solutions GmbH)
Namespace: ProfinetCommon

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: ProfinetCommon

ProfinetDevice

Library Identification

Placeholder: ProfinetDevice
Default Resolution: ProfinetDevice, * (3S - Smart Software Solutions GmbH)
Namespace: ProfinetDevice

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: ProfinetDevice

Remote Procedure Calls

Library Identification

Placeholder: RPC
Default Resolution: Remote Procedure Calls, * (3S - Smart Software Solutions GmbH)
Namespace: RPC

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: RPC

Standard

Library Identification

Placeholder: Standard
Default Resolution: Standard, * (System)
Namespace: Standard

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Standard

StringUtils

Library Identification

Placeholder: StringUtils
Default Resolution: StringUtils, * (System)
Namespace: Stu

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: StringUtils

SysCpuHandling

Library Identification

Placeholder: SysCpuHandling
Default Resolution: SysCpuHandling, * (System)
Namespace: SysCpuHandling

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysCpuHandling

SysFile

Library Identification

Placeholder: SysFile
Default Resolution: SysFile, * (System)
Namespace: SysFile

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysFile

SysMem

Library Identification

Placeholder: SysMem
Default Resolution: SysMem, * (System)
Namespace: SysMem

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysMem

SysSocket

Library Identification

Placeholder: SysSocket
Default Resolution: SysSocket, * (System)
Namespace: SysSocket

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysSocket

SysTarget

Library Identification

Placeholder: SysTarget
Default Resolution: SysTarget, * (System)
Namespace: SysTarget

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTarget

SysTime

Library Identification

Placeholder: SysTime
Default Resolution: SysTime, * (System)
Namespace: SysTime

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTime

SysTypes2 Interfaces

Library Identification

Name: SysTypes2 Interfaces
Version: newest
Company: System
Namespace: SysTypes

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTypes2 Interfaces, * (System)