ModbusChannel (FB)¶
FUNCTION_BLOCK ModbusChannel
Starts the execution of a single configured modbus channel.
- InOut:
- Scope - Name - Type - Initial - Comment - Inout - slave- Input - xExecute- BOOL- Rising edge: Action start
- Falling edge: Resets outputs If a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or aborted (xAbort), or in the event of an error. In this case, the corresponding output values (xDone, xError, iError) are present at the outputs for exactly one cycle. 
 - xAbort- BOOL- If this input is TRUE, the action is stopped immediately and all outputs are reset to their initial values. - iChannelIndex- INT- The Channel Index that shall be executed. An invalid index results in xError = TRUE (without any Modbus specific error code). - Output - xBusy- BOOL- Is TRUE as long as a request is in progress - xDone- BOOL- Is TRUE if a request finished successfully - xError- BOOL- Is TRUE if a request finished unsuccessfully - xAborted- BOOL- Is TRUE after a request in progress has been aborted by “xAbort” - ModbusError- MB_ErrorCodes.UNDEFINED - Specifies the current error as defined in the “MB_ErrorCodes” enumeration 