HTTP_Bridge (FB)¶
FUNCTION_BLOCK HTTP_Bridge EXTENDS CBML.LConTo
Function Block to connect with the Google Cloud Iot Core over HTTP Bridge
- InOut:
- Scope - Name - Type - Initial - Comment - Inherited from - Input - xEnable- BOOL- TRUE: Activates the defined operation- FALSE: Aborts/resets the defined operation- LConTo - udiTimeOut- UDINT- Max. operating time for executing [µs], 0: No operating time limit - LConTo - Output - xDone- BOOL- TRUE: Ready condition reached- LConTo - xBusy- BOOL- TRUE: Operation is running- LConTo - xError- BOOL- TRUE: Error condition reached- LConTo - Input - sproject_id- STRING(255)- PROJECT_ID used by Google IoT CORE - scloud_region- STRING(255)- REGION used by Google IoT CORE - sregistry_id- STRING(255)- REGISTRY_ID used by Google IoT CORE - sdevice_id- STRING(255)- DEVICE_ID used by Google IoT CORE - sUseCaseNamePrivateKey- STRING- Use Case Name for Certificate used for creation of JWT - sCommonNamePrivateKey- STRING- Common Name for Certificate used for creation of JWT - udiJWTExpirationTime- UDINT- 3600 - Expiration Time of the JWT, in [s]. Default 3600s - sSNTPServer- REFERENCE TO STRING(255) - The IP address or the name of a SNTP server to get the UTC time. If the input is not set, then the local system time will be used. - Output - eError- Output Error 