Get_Attribute_List (FB)ΒΆ

FUNCTION_BLOCK Get_Attribute_List EXTENDS BaseService

This function block returns the contents of the selected gettable attributes fo the specified CIP Object class or instance.

Note

Data received and send needs to be swapped. See parent folder.

PROGRAM PLC_PRG
VAR
    arData            : ARRAY[0..5] OF BYTE;
    getAttributeList : ENIP.Get_Attribute_List ;
    arResponse      : ARRAY [0..11] OF BYTE;
END_VAR

getAttributeList(
    xExecute:= ,
    itfEtherNetIPDevice:= EtherNet_IP_Adapter,    (* instance of the device (instance is found in the I/O Mapping of the device) *)
    eClass:= ENIP.CIPClass.TCPIPInterfaceObject, (* cip class which contains the desired attribute *)
    dwInstance:= 1,                              (* value of 0 is class level, range from 1..x is instance level *)
    pRequestData := ADR(arData);                    (* data buffer *)
       udiRequestDataSize := SIZEOF(arData);        (* size of the data buffer *)
       pResponseData := ADR(arResponse);            (* data buffer from the response *)
       udiResponseDataSize := SIZEOF(arResponse);   (* size of the data buffer from the response *)
    xDone=> ,
    xBusy=> ,
    xError=> ,
    eError=> );
    ;
InOut:

Scope

Name

Type

Inherited from

Input

xExecute

BOOL

ETrig

Output

xDone

BOOL

ETrig

xBusy

BOOL

ETrig

xError

BOOL

ETrig

Input

itfEtherNetIPDevice

IEtherNetIPService

BaseService

eClass

CIPClass

BaseService

dwInstance

DWORD

BaseService

tTimeOut

TIME

BaseService

Output

eError

ERROR

BaseService

Input

pRequestData

POINTER TO BYTE

udiRequestDataSize

UDINT

pResponseData

POINTER TO BYTE

udiResponseDataSize

UDINT

Output

udiReceivedDataSize

UDINT