Set_Attributes_All (FB)ΒΆ
FUNCTION_BLOCK Set_Attributes_All EXTENDS BaseService
This function blocks is used for setting the attribute of a specific instance of a CIP object.
Note
Data received and send needs to be swapped. See parent folder.
- InOut:
- Scope - Name - Type - Comment - Inherited from - Input - xExecute- BOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (- xDone,- xError) are present at the outputs for exactly one cycle.- ETrig - Output - xDone- BOOL- TRUE: Action successfully completed- ETrig - xBusy- BOOL- TRUE: Function block active- ETrig - xError- BOOL- TRUE: Error occurred, function block aborts action- FALSE: No error- ETrig - Input - itfEtherNetIPDevice- IEtherNetIPService- BaseService - eClass- BaseService - dwInstance- DWORD- BaseService - Output - eError- BaseService - Input - pData- POINTER TO BYTE - udiDataSize- UDINT
