ETC_CO_SdoWriteDWord (FB)ΒΆ
FUNCTION_BLOCK ETC_CO_SdoWriteDWord
Like ETC_CO_SdoWrite4, this function block is for writing EtherCAT slave parameters. However, the data to be written are transferred not as an array, but in a DWORD (dwData). If byte swapping is necessary it is carried out automatically. The value to be written can thus be specified directly.
- InOut:
Scope
Name
Type
Initial
Comment
Input
xExecute
BOOL
Rising edge: ACTION starts Falling edge: Resets outputs If a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (xDone, xError) are present at the outputs for exactly one cycle.
xAbort
BOOL
FALSE
TRUE: Action is stopped immediately and all outputs are reset to their initial values.
usiCom
USINT
1
Index of master 1: first ETC master
uiDevice
UINT
The physical slave address to access the EtherCAT slave
usiChannel
USINT
1
not used in the moment because channel is set automatically
wIndex
WORD
The index of the CoE object
bySubindex
BYTE
The sub index of the CoE object
udiTimeOut
UDINT
Timeout for operation in ms
dwData
DWORD
The data to be written
usiDataLength
USINT
Number of bytes to be written
Output
xDone
BOOL
TRUE: Action successfully completed
xBusy
BOOL
TRUE: Function block active
xError
BOOL
TRUE: Error occurred, function block aborts action, FALSE: No error
eError
If xError is true then eError shows the error reason
udiSdoAbort
UDINT
The abort code as received from the slave device