CODESYS GmbH
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
Menu
Search
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
  • ByteOrder (Enum)
  • Credentials
    • ICredentials (Interface)
    • ICredentialsProvider (Interface)
      • GetCredentials (Method)
      • IsGetCredentialsFinished (Method)
      • LoginFailed (Method)
      • LoginSucceeded (Method)
      • StartGetCredentials (Method)
    • ICredentialsUserPassword (Interface)
      • Password (Property)
      • Username (Property)
  • Drivers relevant only
    • IDataItem (Interface)
      • Access (Property)
      • Assigner (Property)
      • DriverSpecific (Property)
      • Name (Property)
      • SetError (Method)
      • SizeLocal (Property)
      • SizeRemote (Property)
    • IDataItemValueAssigner (Interface)
      • GetRawValue (Method)
      • SetRawValue (Method)
    • IDriver (Interface)
      • CredentialsHandling (Property)
      • DataByteOrder (Property)
      • Init (Method)
      • RequestFactory (Property)
      • StateMachine (Property)
      • TargetByteOrder (Property)
    • IDriverCDSV3 (Interface)
      • CanSendCDSV3CustomRequest (Method)
    • IDriverCredentialsHandling (Interface)
      • CredentialsNecessary (Property)
      • SetCredentials (Method)
    • IDriverCredentialsHandlingEveryLogin (Interface)
      • AskCredentialsEveryLogin (Property)
    • IDriverCustomRequest (Interface)
      • Request (Property)
      • Response (Property)
    • IDriverLargeRequest (Interface)
      • Finished (Property)
    • IDriverRequest (Interface)
    • IDriverRequestFactory (Interface)
      • CreateReadRequest (Method)
      • CreateWriteRequest (Method)
      • ReleaseRequest (Method)
    • IDriverRequestFactoryCustom (Interface)
      • CreateCustomRequest (Method)
    • IDriverRequestFactoryLargeRequests (Interface)
      • CreateLargeReadRequest (Method)
      • CreateLargeWriteRequest (Method)
    • IDriverRequestFactoryReusable (Interface)
      • CreateReusableRequest (Method)
      • ReusableRequestsSupported (Property)
    • IDriverRequestReusable (Interface)
      • NextOperation (Property)
    • IDriverSpecificData (Interface)
      • Release (Method)
    • IDriverSpecifiedSettings (Interface)
      • ReconnectWaitTime (Method)
      • TimeoutSyncShutdown (Method)
    • IDriverStateMachine (Interface)
      • Connecting (Method)
      • PollRequestResult (Method)
      • ResetAfterError (Method)
      • SendRequest (Method)
      • ShutdownAfterError (Property)
      • ShuttingDown (Method)
      • StartConnect (Method)
      • StartShutdown (Method)
    • IDriverStateMachine2 (Interface)
      • WaitingForCommSetting (Method)
    • IDriverStateMachineNotifyBeforeShutdown (Interface)
      • BeforeShutdown (Method)
    • IDriverStateMachineShutdownTimeout (Interface)
      • ShutdownTimedout (Method)
    • IDriverTraceAddressInfoProvider (Interface)
      • CreateTraceAddressInfoWriter (Method)
      • GetPointerSizeInBytes (Method)
      • ReleaseTraceAddressInfoWriter (Method)
    • ReusableRequestOperations (Enum)
  • ETraceAddressFlags (Enum)
  • Errors (GVL)
  • ICDSV3Request (Interface)
    • ContentData (Property)
    • ContentSize (Property)
    • Service (Property)
    • ServiceGroup (Property)
    • SetContentData (Method)
  • ICDSV3RequestHandling (Interface)
    • CreateCDSV3Request (Method)
    • TargetByteorder (Property)
  • ICDSV3Response (Interface)
    • ContentData (Property)
    • ContentSize (Property)
    • RawData (Property)
    • RawSize (Property)
  • ICDSV3ServiceWriter (Interface)
  • ICustomRequest (Interface)
  • ICustomRequestCallback (Interface)
    • RequestFinished (Method)
  • ICustomRequestHandling (Interface)
    • ReleaseRequest (Method)
  • ICustomResponse (Interface)
  • IDataItemBase (Interface)
    • ErrorCode (Property)
    • Quality (Property)
    • TimeStamp (Property)
    • TypeClass (Property)
  • IDataItemList (Interface)
    • Clear (Method)
    • Count (Property)
    • CreateAndAdd (Method)
    • GetItem (Method)
  • IDataItemListExpanding (Interface)
    • CreateAndAddExpanding (Method)
  • IDataItemListPersistant (Interface)
    • FinishedAdding (Method)
    • Usage (Property)
    • UsageDetails (Property)
  • IDatasource (Interface)
    • CustomRequestHandling (Property)
    • EnqueueCustomRequest (Method)
    • SetCredentialsProvider (Method)
  • IDatasource2 (Interface)
    • Error (Property)
    • State (Property)
  • IDatasource3 (Interface)
    • SetUpdateRateReduction (Method)
    • UpdateRate (Property)
  • IDatasourceTraceAddressInfoProvider (Interface)
    • CreateTraceAddressInfoWriter (Method)
    • GetPointerSizeInBytes (Method)
    • ReleaseTraceAddressInfoWriter (Method)
  • IDatasourcesActionRecord (Interface)
  • IDatasourcesFrameManager (Interface)
    • GetCount (Method)
    • GetReplacedPath (Method)
    • GetReplacementInfo (Method)
  • IDatasourcesMgr (Interface)
    • ActionRecordDelete (Method)
    • ActionRecordReplay (Method)
    • ActionRecordingGetResult (Method)
    • ActionRecordingStart (Method)
    • AllItemsOk (Method)
    • BeginDataConfiguration (Method)
    • CreateItemList (Method)
    • DeleteItemList (Method)
    • EndDataConfiguration (Method)
    • GetDatasource (Method)
    • GetItemInfo (Method)
    • ReadItemsSync (Method)
    • ReleaseData (Method)
    • SetCredentialsProvider (Method)
    • UseData (Method)
    • WriteItemsSync (Method)
  • IDatasourcesMgr2 (Interface)
    • AddNotificationClient (Method)
    • CreatePersistantItemList (Method)
    • DeletePersistantItemList (Method)
    • GetPersistantItemList (Method)
    • Lock (Method)
    • PersistantItemListCount (Property)
    • RemoveNotificationClient (Method)
    • Unlock (Method)
  • IDatasourcesMgr3 (Interface)
    • UseDataExpanding (Method)
  • IDatasourcesMgr4 (Interface)
    • CountDatasources (Property)
    • GetDatasourceItfByIndex (Method)
  • INotificationClient (Interface)
    • ListOperationDone (Method)
    • ListOperationStart (Method)
    • ListValueRead (Method)
    • ListValueWrite (Method)
    • ReadRequestDone (Method)
    • ReadRequestStart (Method)
    • SingleValueRead (Method)
    • SingleValueWrite (Method)
    • WriteRequestDone (Method)
    • WriteRequestStart (Method)
  • ITraceAddressInfoWriter (Interface)
    • GetAddressFlags (Method)
    • GetSize (Method)
    • GetType (Method)
    • Release (Method)
    • WriteAddressInfo (Method)
  • ItemAccess (Enum)
  • ItemName (Struct)
  • ItemNameType (Enum)
  • ItemQuality (Enum)
  • MonitoringState (Enum)
  • PersistantItemListUsage (Enum)
  • ReplacementInfo (Struct)
  • File and Project Information
  • Library Reference
    • Base Interfaces
      • Library Identification
      • Library Properties
    • SysTypes2 Interfaces
      • Library Identification
      • Library Properties
Datasources Interfaces
  • Docs »
  • ICDSV3Response (ITF)

ICDSV3Response (ITF)ΒΆ

INTERFACE ICDSV3Response EXTENDS ICustomResponse

Properties:

ContentData

ContentSize

RawData

RawSize

Structure:

  • ContentData (Property)
  • ContentSize (Property)
  • RawData (Property)
  • RawSize (Property)
top

CODESYS Group | We software Automation. to software
['sɒftwɛər]
transitive verb
__softwared/softwaring
: to develop software
// to software automation: to develop software for automation purposes

The CODESYS Group is the manufacturer of CODESYS, the leading hardware-independent IEC 61131-3 automation software for developing and engineering controller applications.
CODESYS® is a registered trademark.

CODESYS GmbH
A member of the CODESYS Group
Memminger Straße 151, 87439 Kempten
Germany
Tel.: +49-831-54031-0
info@codesys.com
  • Legal Notice
  • Privacy Policy
LinkedIn Youtube RSS Downloads Login CODESYS Store
© 2022 CODESYS GmbH | A member of the CODESYS Group