Services (GVL)ΒΆ
- Attributes:
qualified_only- InOut:
Scope
Name
Type
Initial
Comment
Constant
SG_Device
UINT16#1
Service Groups
SG_Application
UINT16#2
SG_Monitoring
UINT16#3
SG_Visualization
UINT16#4
SG_IecVarAccess
UINT16#9
SG_TraceManager
UINT16#F
SG_AlarmManager
UINT16#18
SG_Monitoring2
UINT16#1B
SG_TrendStorage
UINT16#1E
SRV_DevGetTargetId
UINT16#1
Device Services
SRV_DevLogin
UINT16#2
SRV_DevLogout
UINT16#3
SRV_DevSessionCreate
UINT16#A
TAG_DevLoginUsername
UINT16#10
TAG_DevLoginPassword
UINT16#11
TAG_DevLoginReplyResult
UINT16#20
TAG_DevLoginReplySessionId
UINT16#21
TAG_DevLoginCryptType
UINT16#22
TAG_DevLoginCryptChallenge
UINT16#23
TAG_DevLoginReplySettingFlags
UINT16#24
TAG_DevLoginCredentials
UINT16#81
TAG_DevLoginReply
UINT16#82
TAG_DevLogout
UINT16#0
no data read out at the moment so sending this value is ok, even if it is not defined at all
TAG_DevSessionCreateClientType
UINT16#40
TAG_DevSessionCreateClientName
UINT16#41
TAG_DevSessionCreateClientVendor
UINT16#42
TAG_DevSessionCreateClientHostName
UINT16#43
TAG_DevSessionCreateClientVersion
UINT16#44
TAG_DevSessionCreateClientCDSVersion
UINT16#45
TAG_DevSessionCreateClientAuthType
UINT16#46
TAG_DevSessionCreateClientIdentifier
UINT16#83
TAG_UsrMgrCryptType
UINT16#22
TAG_UsrMgrCryptStep
UINT16#25
TAG_UsrMgrCryptNonce
UINT16#26
TAG_UsrMgrCryptPubKey
UINT16#27
TAG_UsrMgrCredentials
UINT16#81
TAG_UsrMgrUser
UINT16#10
TAG_UsrMgrPassword
UINT16#11
TAG_UsrMgrOnlAccResult
UINT16#FF82
TAG_UsrMgrOnlAccReplyCryptType
UINT16#FF22
TAG_UsrMgrOnlAccReplyCryptChallenge
UINT16#FF23
SRV_AppLogin
UINT16#1
Application Services
SRV_AppLogout
UINT16#2
TAG_AppLogin
UINT16#1
TAG_AppDesc
UINT16#81
TAG_AppName
UINT16#1
TAG_AppRights
UINT16#11
TAG_AppId
UINT16#11
TAG_AppResult
UINT16#10
TAG_AppReply
UINT16#81
TAG_AppLogout
UINT16#0
SRV_MonMonitoringListOnce
UINT16#1
Monitoring Services
SRV_MonWriteVariables
UINT16#2
TAG_Monitoring
UINT16#81
TAG_MonApplication
UINT16#10
TAG_MonSimpleDataType
UINT16#11
TAG_MonStackRelative
UINT16#12
only to be complete, probably not important
TAG_MonCompoData
UINT16#13
TAG_MonVarId
UINT16#14
TAG_MonParameterType
UINT16#15
TAG_MonBit
UINT16#18
TAG_PropertyCallRef
UINT16#20
TAG_MonErrorResponse
UINT16#1
TAG_MonReply
UINT16#1
SRV_Mon2Read
UINT16#1
Monitoring 2 Services
SRV_Mon2Write
UINT16#2
TAG_Mon2AppHeader
UINT16#1
TAG_Mon2ReadExpList
UINT16#2
TAG_Mon2WriteExpList
UINT16#3
TAG_Mon2ReadValueList
UINT16#40
TAG_Mon2ReadError
UINT16#41
TAG_TrcVariableAddressArea
UINT16#23
Trace
TAG_TrcVariableAddressOffset
UINT16#24
TAG_TrcInstanceArea
UINT16#43
TAG_TrcInstanceOffset
UINT16#44
TAG_TrcPropertyArea
UINT16#45
TAG_TrcPropertyOffset
UINT16#46
TAG_GeneralError
UINT16#FF7F
TAG_ExtendedErrorInfo
UINT16#FF7E
TAG_Online_Access_Result
UINT16#FF82