IoMgrLockLeave (FUN)¶
FUNCTION IoMgrLockLeave : RTS_IEC_RESULT
This function releases the mutual-exclusion locks (that were acquired with the function IoMgrLockEnter()) for the given operations.
IMPLEMENTATION NOTE: The behavior of the dwLockScope parameter can’t be implemented on all platforms.
Platforms without synchronization functionality may not be able to implement this behavior.
IoMgrEmbedded of the CODESYSControlEmbedded runtime system for example can only disable and enable all interrupts.
- InOut:
Scope
Name
Type
Comment
Return
IoMgrLockLeaveRTS_IEC_RESULT- error code
ERR_OK: Locks were successfully released.
ERR_PARAMETER: The
pbyIoDrvparameter isNULL(only implementations that use this parameter), or thedwLockScopeparameter has none of the GVL LockScopes set (only implementations that use this parameter).ERR_FAILED: No driver entry for pbyIoDrv found in device pool.
Input
hIoDrvRTS_IEC_HANDLEHandle to the driver instance which is returned by the function IoMgrRegisterInstance2().
dwLockScopeDWORDThe operations for which to release the locks. See GVL LockScopes for detailed information.