EventIDs (GVL)ΒΆ
- InOut:
Scope
Name
Type
Initial
Comment
Constant
CMPID_CmpIoConfig
DWORD16#A9
EVTPARAMID_CmpIoConfigOnlineChange
WORD16#1
Parameter ID
EVTVERSION_CmpIoConfigOnlineChange
WORD16#1
Parameter version
EVT_OnlineChangeForIoDevices
DWORD16#10001
Event is sent to inform IO devices about status of online change.
Status_OnlineChangeBegin
DWORD16#1
status bit in EVTPARAM_CmpIoMgr_OnlineChange: begin of OnlineChange
Status_OnlineChangeEnd
DWORD16#2
status bit in EVTPARAM_CmpIoMgr_OnlineChange: end of OnlineChange
Status_OnlineChangeDeviceAdded
DWORD16#3
status bit in EVTPARAM_CmpIoMgr_OnlineChange: device added
Status_OnlineChangeDeviceRemoved
DWORD16#4
status bit in EVTPARAM_CmpIoMgr_OnlineChange: device removed
Status_OnlineChangeDeviceChanged
DWORD16#5
status bit in EVTPARAM_CmpIoMgr_OnlineChange: Device changed (number of parameters changed)
Status_OnlineChangeDeviceMoved
DWORD16#6
status bit in EVTPARAM_CmpIoMgr_OnlineChange: Device moved
Status_OnlineChangeDeviceEnable
DWORD16#7