ERR_OK

UDINT

16#0

Ok

ERR_FAILED

UDINT

16#1

General error - to be used only for internal errors

ERR_PARAMETER

UDINT

16#2

Invalid parameter for this operation

ERR_NOTINITIALIZED

UDINT

16#3

Function cannot be executed, since component has not been initialized yet. It may work later, though

ERR_VERSION

UDINT

16#4

Version conflict

ERR_TIMEOUT

UDINT

16#5

Operation timed out

ERR_NOBUFFER

UDINT

16#6

Insufficient memory to carry out the request

ERR_PENDING

UDINT

16#A

For async-calls: call not complete, yet

ERR_NUMPENDING

UDINT

16#B

To many pending calls. Try later

ERR_NOTIMPLEMENTED

UDINT

16#C

The function is not implemented

ERR_INVALIDID

UDINT

16#D

No object with the provided id found

ERR_OVERFLOW

UDINT

16#E

Integer overflow

ERR_BUFFERSIZE

UDINT

16#F

The size of a buffer is to small or invalid

ERR_NO_OBJECT

UDINT

16#10

No object with this specified name available

ERR_NOMEMORY

UDINT

16#11

No heap memory available

ERR_DUPLICATE

UDINT

16#12

An object with the same name is still available

ERR_MEMORY_OVERWRITE

UDINT

16#13

Heap memory was written out of bounds! Memory overwrite error

ERR_INVALID_HANDLE

UDINT

16#14

Invalid handle TO an object

ERR_END_OF_OBJECT

UDINT

16#15

End OF object reached

ERR_NO_CHANGE

UDINT

16#16

No changes done

ERR_INVALID_INTERFACE

UDINT

16#17

Invalid OR unknown INTERFACE

ERR_NOT_SUPPORTED

UDINT

16#18

Functionality NOT supported

ERR_NO_ACCESS_RIGHTS

UDINT

16#19

No access rights FOR THIS operation

ERR_OUT_OF_LIMITS

UDINT

16#1A

Specified limits OF a resource exceeded

ERR_ENTRIES_REMAINING

UDINT

16#1B

Remaining entries that could NOT be transmitted because OF buffer limitation

ERR_INVALID_SESSION_ID

UDINT

16#1C

Invalid online sessionid

ERR_EXCEPTION

UDINT

16#1D

Exception occurred

ERR_SIGNATURE_MISMATCH

UDINT

16#1E

Signature mismatch OF an api FUNCTION

ERR_VERSION_MISMATCH

UDINT

16#1F

Version mismatch

ERR_TYPE_MISMATCH

UDINT

16#20

TYPE mismatch

ERR_ID_MISMATCH

UDINT

16#21

ID mismatch

ERR_NO_CONSISTENCY

UDINT

16#22

Consistency error

ERR_NO_COMM_CYCLE

UDINT

16#23

No COMM_CYCLE needed

ERR_DONT_SUSPEND_TASK

UDINT

16#24

DO NOT suspend task after an exception

ERR_MEMORY_LOCK_FAILED

UDINT

16#25

Memory cannot be locked in THIS operation

ERR_LICENSE_MISSING

UDINT

16#26

License missing FOR the runtime

ERR_OPERATION_DENIED

UDINT

16#27

Operation denied

ERR_DEVICE

UDINT

16#28

Device error

ERR_DISK_FULL

UDINT

16#29

Disk full

ERR_CRC_FAILED

UDINT

16#30

Internal use in runtime

ERR_MEDIA_ERASE

UDINT

16#31

Internal use in runtime

ERR_FILE_ERROR

UDINT

16#32

File error. e.g. cannot open a file FOR writing because it could be write PROTECTED

ERR_NO_RETAIN_MEMORY

UDINT

16#33

No RETAIN memory available

ERR_OUT_OF_LIMITS_MIN

UDINT

16#34

Specified minimum-limit of a resource exceeded

ERR_OUT_OF_LIMITS_MAX

UDINT

16#35

Specified maximum-limit of a resource exceeded

ERR_SIZE_MISMATCH

UDINT

16#36

Size mismatch

ERR_CALL_AGAIN

UDINT

16#37

Operation is not yet finished, call function again to proceed

ERR_NOTHING_TO_DO

UDINT

16#38

Operation has nothing TO DO. No execution.

ERR_SECURITY_CHECKS_FAILED

UDINT

16#39

Some security checks have failed. THIS is a generic error code TO report THIS error over PUBLIC channels. In THIS CASE the error code doesn’t provide a detailed cause for the error. */

ERR_INVALID_SEQUENCE

UDINT

16#3A

ERR_INVALID_REFERENCE

UDINT

16#3B

Dereferencing an IEC reference in IecVarAccess failed due to invalid destination address, e. G. NULL.

ERR_CONVERSION_INCOMPLETE

UDINT

16#3C

Conversion of string encodings was not lossless.

ERR_TOO_MANY_RETRIES

UDINT

16#3D

Too many retries OF an ACTION

ERR_ALIGNMENT

UDINT

16#3E

There is an unaligned access on memory detected.

ERR_CHANGE_PASSWORD

UDINT

16#3F

The password has to be changed

ERR_REAUTHENTICATE

UDINT

16#40

The user has to reauthenticate oneself

ERR_RELOGIN

UDINT

16#41

The user has to relogin

ERR_INVALID_URL

UDINT

16#42

An URL was not valid.

ERR_INVALID_STATE

UDINT

16#43

The component state does not allow to call this function.

ERR_USER_MISMATCH

UDINT

16#44

User mismatch

ERR_NOT_READY_YET

UDINT

16#45

The service is not ready yet. Try again later

ERR_ACTIVATE_USERMGMT

UDINT

16#46

The user management has to be activated.

ERR_NO_USERMGMT

UDINT

16#47

A login was done with a user name, but no user management is active.

ERR_INVALID_ENCODING

UDINT

16#48

A string encoding was not correct.

ERR_TARGET_MISMATCH

UDINT

16#49

Target mismatch detected

ERR_CLIENT_IN_RO_MODE

UDINT

16#4A

Client is in readonly mode and has no rights for this service.

ERR_LICENSE_EXCEEDED

UDINT

16#4B

License is not sufficient

ERR_ASYNC_EXCEPTION

UDINT

16#4C

Exception occured during execution of async service task

ERR_NO_SIGNATURE

UDINT

16#4D

Object contains no siganture

ERR_PASSWORD_POLICY

UDINT

16#4E

Password does not fulfill the password policy requirements

ERR_LICENSE_EXPIRED

UDINT

16#4F

License expired

ERR_LICENSE_OCCUPIED

UDINT

16#50

License occupied

ERR_LICENSE_MAINTENANCE_PERIOD_OUTSIDE

UDINT

16#51

Maintenance period mismatch

ERR_SOCK_NOTINITIALIZED

UDINT

16#201

Socket not initialized

ERR_SOCK_NOTSOCKET

UDINT

16#202

The provided socket handle is invalid

ERR_SOCK_AFUNSUPPORTED

UDINT

16#203

The address family is NOT supported

ERR_SOCK_PROTOUNSUPPORTED

UDINT

16#204

Protocol is NOT supported

ERR_SOCK_NOBUFFER

UDINT

16#205

NOT enough buffer TO handle the request

ERR_SOCK_WOULDBLOCK

UDINT

16#206

Socket is in nonblocking mode but THIS call would block

ERR_SOCK_ADDRINUSE

UDINT

16#207

The provided address is already in use

ERR_SOCK_ADDRNOTAVAILABLE

UDINT

16#208

The provided address is NOT available on THIS computer

ERR_SOCK_CONNREFUSED

UDINT

16#209

Connection has been refused BY the remote host

ERR_SOCK_TIMEDOUT

UDINT

16#20A

Operation timed out

ERR_SOCK_HOSTNOTFOUND

UDINT

16#20B

The host has NOT been found

ERR_SOCK_HOSTUNREACHABLE

UDINT

16#20C

Host is unreachable

ERR_SOCK_ISCONNECTED

UDINT

16#20D

Socket is already connected

ERR_SOCK_NOTCONNECTED

UDINT

16#20E

The socket is NOT connected

ERR_SOCK_SHUTDOWN

UDINT

16#20F

Shutdown has been called on the socket

ERR_SOCK_MSGSIZE

UDINT

16#210

FOR sockets OF TYPE DGRAM. The package TO send exceeds the maximum package size

ERR_SOCK_CLOSED

UDINT

16#211

Socket has been gracefully closed. No more send/receives allowed

ERR_L7_TAG_MISSING

UDINT

16#300

Tag missing in online communication buffer

ERR_L7_UNKNOWNCMDGROUP

UDINT

16#301

Unknown command group

ERR_L7_UNKNOWNCMD

UDINT

16#302

Unknown command (within a valid command group)

ERR_L7_INCOMPLETE

UDINT

16#303

Level 7 service incomplete

ERR_CERT_OK

UDINT

ERR_OK

Certificate validation error codes

ERR_CERT_UNABLE_TO_GET_ISSUER_CERT

UDINT

16#701

illegal error (FOR uninitialized values, TO avoid ERR_CERT_OK) */

ERR_CERT_UNABLE_TO_GET_CRL

UDINT

16#702

ERR_CERT_UNABLE_TO_DECRYPT_CERT_SIGNATURE

UDINT

16#703

ERR_CERT_UNABLE_TO_DECRYPT_CRL_SIGNATURE

UDINT

16#704

ERR_CERT_UNABLE_TO_DECODE_ISSUER_PUBLIC_KEY

UDINT

16#705

ERR_CERT_SIGNATURE_FAILURE

UDINT

16#706

ERR_CERT_CRL_SIGNATURE_FAILURE

UDINT

16#707

ERR_CERT_NOT_YET_VALID

UDINT

16#708

ERR_CERT_HAS_EXPIRED

UDINT

16#709

ERR_CERT_CRL_NOT_YET_VALID

UDINT

16#70A

ERR_CERT_CRL_HAS_EXPIRED

UDINT

16#70B

ERR_CERT_ERROR_IN_CERT_NOT_BEFORE_FIELD

UDINT

16#70C

ERR_CERT_ERROR_IN_CERT_NOT_AFTER_FIELD

UDINT

16#70D

ERR_CERT_ERROR_IN_CRL_LAST_UPDATE_FIELD

UDINT

16#70E

ERR_CERT_ERROR_IN_CRL_NEXT_UPDATE_FIELD

UDINT

16#70F

ERR_CERT_OUT_OF_MEM

UDINT

16#710

ERR_CERT_DEPTH_ZERO_SELF_SIGNED_CERT

UDINT

16#711

ERR_CERT_SELF_SIGNED_CERT_IN_CHAIN

UDINT

16#712

ERR_CERT_UNABLE_TO_GET_ISSUER_CERT_LOCALLY

UDINT

16#713

ERR_CERT_UNABLE_TO_VERIFY_LEAF_SIGNATURE

UDINT

16#714

ERR_CERT_CHAIN_TOO_LONG

UDINT

16#715

ERR_CERT_REVOKED

UDINT

16#716

ERR_CERT_INVALID_CA

UDINT

16#717

ERR_CERT_PATH_LENGTH_EXCEEDED

UDINT

16#718

ERR_CERT_INVALID_PURPOSE

UDINT

16#719

ERR_CERT_UNTRUSTED

UDINT

16#71A

ERR_CERT_REJECTED

UDINT

16#71B

ERR_CERT_SUBJECT_ISSUER_MISMATCH

UDINT

16#71C

These are ‘informational’ when looking for issuer cert

ERR_CERT_AKID_SKID_MISMATCH

UDINT

16#71D

ERR_CERT_AKID_ISSUER_SERIAL_MISMATCH

UDINT

16#71E

ERR_CERT_KEYUSAGE_NO_CERTSIGN

UDINT

16#71F

ERR_CERT_UNABLE_TO_GET_CRL_ISSUER

UDINT

16#720

ERR_CERT_UNHANDLED_CRITICAL_EXTENSION

UDINT

16#721

ERR_CERT_KEYUSAGE_NO_CRL_SIGN

UDINT

16#722

ERR_CERT_UNHANDLED_CRITICAL_CRL_EXTENSION

UDINT

16#723

ERR_CERT_INVALID_NON_CA

UDINT

16#724

ERR_CERT_PROXY_PATH_LENGTH_EXCEEDED

UDINT

16#725

ERR_CERT_KEYUSAGE_NO_DIGITAL_SIGNATURE

UDINT

16#726

ERR_CERT_PROXY_CERTIFICATES_NOT_ALLOWED

UDINT

16#727

ERR_CERT_INVALID_EXTENSION

UDINT

16#728

ERR_CERT_INVALID_POLICY_EXTENSION

UDINT

16#729

ERR_CERT_NO_EXPLICIT_POLICY

UDINT

16#72A

ERR_CERT_DIFFERENT_CRL_SCOPE

UDINT

16#72B

ERR_CERT_UNSUPPORTED_EXTENSION_FEATURE

UDINT

16#72C

ERR_CERT_UNNESTED_RESOURCE

UDINT

16#72D

ERR_CERT_PERMITTED_VIOLATION

UDINT

16#72E

ERR_CERT_EXCLUDED_VIOLATION

UDINT

16#72F

ERR_CERT_SUBTREE_MINMAX

UDINT

16#730

ERR_CERT_UNSUPPORTED_CONSTRAINT_TYPE

UDINT

16#731

ERR_CERT_UNSUPPORTED_CONSTRAINT_SYNTAX

UDINT

16#732

ERR_CERT_UNSUPPORTED_NAME_SYNTAX

UDINT

16#733

ERR_CERT_CRL_PATH_VALIDATION_ERROR

UDINT

16#734

ERR_CERT_APPLICATION_VERIFICATION

UDINT

16#735

The application is not happy

ERR_CERT_MISSING

UDINT

16#736

ERR_CERT_UNKNOWN_ERROR

UDINT

16#737

ERR_CERT_UNABLE_TO_GET_ISSUER_CRL

UDINT

16#738

ERR_CERT_CHAIN_INCOMPLETE

UDINT

16#739

ERR_REDU_TOO_TAGS

UDINT

16#B00

Visu redundancy errors

ERR_REDU_MEMORY

UDINT

16#B01

ERR_REDU_CLIENT_CREATION_ERR

UDINT

16#B02