Errors (GVL)¶
- Attributes:
qualified_only- InOut:
Scope
Name
Type
Initial
Comment
Constant
ERR_OK
UDINT16#0
Ok
ERR_FAILED
UDINT16#1
General error - to be used only for internal errors
ERR_PARAMETER
UDINT16#2
Invalid parameter for this operation
ERR_NOTINITIALIZED
UDINT16#3
Function cannot be executed, since component has not been initialized yet. It may work later, though
ERR_VERSION
UDINT16#4
Version conflict
ERR_TIMEOUT
UDINT16#5
Operation timed out
ERR_NOBUFFER
UDINT16#6
Insufficient memory to carry out the request
ERR_PENDING
UDINT16#A
For async-calls: call not complete, yet
ERR_NUMPENDING
UDINT16#B
To many pending calls. Try later
ERR_NOTIMPLEMENTED
UDINT16#C
The function is not implemented
ERR_INVALIDID
UDINT16#D
No object with the provided id found
ERR_OVERFLOW
UDINT16#E
Integer overflow
ERR_BUFFERSIZE
UDINT16#F
The size of a buffer is to small or invalid
ERR_NO_OBJECT
UDINT16#10
No object with this specified name available
ERR_NOMEMORY
UDINT16#11
No heap memory available
ERR_DUPLICATE
UDINT16#12
An object with the same name is still available
ERR_MEMORY_OVERWRITE
UDINT16#13
Heap memory was written out of bounds! Memory overwrite error
ERR_INVALID_HANDLE
UDINT16#14
Invalid handle TO an object
ERR_END_OF_OBJECT
UDINT16#15
End OF object reached
ERR_NO_CHANGE
UDINT16#16
No changes done
ERR_INVALID_INTERFACE
UDINT16#17
Invalid OR unknown INTERFACE
ERR_NOT_SUPPORTED
UDINT16#18
Functionality NOT supported
ERR_NO_ACCESS_RIGHTS
UDINT16#19
No access rights FOR THIS operation
ERR_OUT_OF_LIMITS
UDINT16#1A
Specified limits OF a resource exceeded
ERR_ENTRIES_REMAINING
UDINT16#1B
Remaining entries that could NOT be transmitted because OF buffer limitation
ERR_INVALID_SESSION_ID
UDINT16#1C
Invalid online sessionid
ERR_EXCEPTION
UDINT16#1D
Exception occurred
ERR_SIGNATURE_MISMATCH
UDINT16#1E
Signature mismatch OF an api FUNCTION
ERR_VERSION_MISMATCH
UDINT16#1F
Version mismatch
ERR_TYPE_MISMATCH
UDINT16#20
TYPE mismatch
ERR_ID_MISMATCH
UDINT16#21
ID mismatch
ERR_NO_CONSISTENCY
UDINT16#22
Consistency error
ERR_NO_COMM_CYCLE
UDINT16#23
No COMM_CYCLE needed
ERR_DONT_SUSPEND_TASK
UDINT16#24
DO NOT suspend task after an exception
ERR_MEMORY_LOCK_FAILED
UDINT16#25
Memory cannot be locked in THIS operation
ERR_LICENSE_MISSING
UDINT16#26
License missing FOR the runtime
ERR_OPERATION_DENIED
UDINT16#27
Operation denied
ERR_DEVICE
UDINT16#28
Device error
ERR_DISK_FULL
UDINT16#29
Disk full
ERR_CRC_FAILED
UDINT16#30
Internal use in runtime
ERR_MEDIA_ERASE
UDINT16#31
Internal use in runtime
ERR_FILE_ERROR
UDINT16#32
File error. e.g. cannot open a file FOR writing because it could be write PROTECTED
ERR_NO_RETAIN_MEMORY
UDINT16#33
No RETAIN memory available
ERR_OUT_OF_LIMITS_MIN
UDINT16#34
Specified minimum-limit of a resource exceeded
ERR_OUT_OF_LIMITS_MAX
UDINT16#35
Specified maximum-limit of a resource exceeded
ERR_SIZE_MISMATCH
UDINT16#36
Size mismatch
ERR_CALL_AGAIN
UDINT16#37
Operation is not yet finished, call function again to proceed
ERR_NOTHING_TO_DO
UDINT16#38
Operation has nothing TO DO. No execution.
ERR_SECURITY_CHECKS_FAILED
UDINT16#39
Some security checks have failed. THIS is a generic error code TO report THIS error over PUBLIC channels. In THIS CASE the error code doesn’t provide a detailed cause for the error. */
ERR_INVALID_SEQUENCE
UDINT16#3A
ERR_INVALID_REFERENCE
UDINT16#3B
Dereferencing an IEC reference in IecVarAccess failed due to invalid destination address, e. G. NULL.
ERR_CONVERSION_INCOMPLETE
UDINT16#3C
Conversion of string encodings was not lossless.
ERR_SOCK_NOTINITIALIZED
UDINT16#201
Socket not initialized
ERR_SOCK_NOTSOCKET
UDINT16#202
The provided socket handle is invalid
ERR_SOCK_AFUNSUPPORTED
UDINT16#203
The address family is NOT supported
ERR_SOCK_PROTOUNSUPPORTED
UDINT16#204
Protocol is NOT supported
ERR_SOCK_NOBUFFER
UDINT16#205
NOT enough buffer TO handle the request
ERR_SOCK_WOULDBLOCK
UDINT16#206
Socket is in nonblocking mode but THIS call would block
ERR_SOCK_ADDRINUSE
UDINT16#207
The provided address is already in use
ERR_SOCK_ADDRNOTAVAILABLE
UDINT16#208
The provided address is NOT available on THIS computer
ERR_SOCK_CONNREFUSED
UDINT16#209
Connection has been refused BY the remote host
ERR_SOCK_TIMEDOUT
UDINT16#20A
Operation timed out
ERR_SOCK_HOSTNOTFOUND
UDINT16#20B
The host has NOT been found
ERR_SOCK_HOSTUNREACHABLE
UDINT16#20C
Host is unreachable
ERR_SOCK_ISCONNECTED
UDINT16#20D
Socket is already connected
ERR_SOCK_NOTCONNECTED
UDINT16#20E
The socket is NOT connected
ERR_SOCK_SHUTDOWN
UDINT16#20F
Shutdown has been called on the socket
ERR_SOCK_MSGSIZE
UDINT16#210
FOR sockets OF TYPE DGRAM. The package TO send exceeds the maximum package size
ERR_SOCK_CLOSED
UDINT16#211
Socket has been gracefully closed. No more send/receives allowed
ERR_L7_TAG_MISSING
UDINT16#300
Tag missing in online communication buffer
ERR_L7_UNKNOWNCMDGROUP
UDINT16#301
Unknown command group
ERR_L7_UNKNOWNCMD
UDINT16#302
Unknown command (within a valid command group)
ERR_L7_INCOMPLETE
UDINT16#303
Level 7 service incomplete
ERR_CERT_OK
UDINTERR_OK
Certificate validation error codes
ERR_CERT_UNABLE_TO_GET_ISSUER_CERT
UDINT16#701
illegal error (FOR uninitialized values, TO avoid ERR_CERT_OK) */
ERR_CERT_UNABLE_TO_GET_CRL
UDINT16#702
ERR_CERT_UNABLE_TO_DECRYPT_CERT_SIGNATURE
UDINT16#703
ERR_CERT_UNABLE_TO_DECRYPT_CRL_SIGNATURE
UDINT16#704
ERR_CERT_UNABLE_TO_DECODE_ISSUER_PUBLIC_KEY
UDINT16#705
ERR_CERT_SIGNATURE_FAILURE
UDINT16#706
ERR_CERT_CRL_SIGNATURE_FAILURE
UDINT16#707
ERR_CERT_NOT_YET_VALID
UDINT16#708
ERR_CERT_HAS_EXPIRED
UDINT16#709
ERR_CERT_CRL_NOT_YET_VALID
UDINT16#70A
ERR_CERT_CRL_HAS_EXPIRED
UDINT16#70B
ERR_CERT_ERROR_IN_CERT_NOT_BEFORE_FIELD
UDINT16#70C
ERR_CERT_ERROR_IN_CERT_NOT_AFTER_FIELD
UDINT16#70D
ERR_CERT_ERROR_IN_CRL_LAST_UPDATE_FIELD
UDINT16#70E
ERR_CERT_ERROR_IN_CRL_NEXT_UPDATE_FIELD
UDINT16#70F
ERR_CERT_OUT_OF_MEM
UDINT16#710
ERR_CERT_DEPTH_ZERO_SELF_SIGNED_CERT
UDINT16#711
ERR_CERT_SELF_SIGNED_CERT_IN_CHAIN
UDINT16#712
ERR_CERT_UNABLE_TO_GET_ISSUER_CERT_LOCALLY
UDINT16#713
ERR_CERT_UNABLE_TO_VERIFY_LEAF_SIGNATURE
UDINT16#714
ERR_CERT_CHAIN_TOO_LONG
UDINT16#715
ERR_CERT_REVOKED
UDINT16#716
ERR_CERT_INVALID_CA
UDINT16#717
ERR_CERT_PATH_LENGTH_EXCEEDED
UDINT16#718
ERR_CERT_INVALID_PURPOSE
UDINT16#719
ERR_CERT_UNTRUSTED
UDINT16#71A
ERR_CERT_REJECTED
UDINT16#71B
ERR_CERT_SUBJECT_ISSUER_MISMATCH
UDINT16#71C
These are ‘informational’ when looking for issuer cert
ERR_CERT_AKID_SKID_MISMATCH
UDINT16#71D
ERR_CERT_AKID_ISSUER_SERIAL_MISMATCH
UDINT16#71E
ERR_CERT_KEYUSAGE_NO_CERTSIGN
UDINT16#71F
ERR_CERT_UNABLE_TO_GET_CRL_ISSUER
UDINT16#720
ERR_CERT_UNHANDLED_CRITICAL_EXTENSION
UDINT16#721
ERR_CERT_KEYUSAGE_NO_CRL_SIGN
UDINT16#722
ERR_CERT_UNHANDLED_CRITICAL_CRL_EXTENSION
UDINT16#723
ERR_CERT_INVALID_NON_CA
UDINT16#724
ERR_CERT_PROXY_PATH_LENGTH_EXCEEDED
UDINT16#725
ERR_CERT_KEYUSAGE_NO_DIGITAL_SIGNATURE
UDINT16#726
ERR_CERT_PROXY_CERTIFICATES_NOT_ALLOWED
UDINT16#727
ERR_CERT_INVALID_EXTENSION
UDINT16#728
ERR_CERT_INVALID_POLICY_EXTENSION
UDINT16#729
ERR_CERT_NO_EXPLICIT_POLICY
UDINT16#72A
ERR_CERT_DIFFERENT_CRL_SCOPE
UDINT16#72B
ERR_CERT_UNSUPPORTED_EXTENSION_FEATURE
UDINT16#72C
ERR_CERT_UNNESTED_RESOURCE
UDINT16#72D
ERR_CERT_PERMITTED_VIOLATION
UDINT16#72E
ERR_CERT_EXCLUDED_VIOLATION
UDINT16#72F
ERR_CERT_SUBTREE_MINMAX
UDINT16#730
ERR_CERT_UNSUPPORTED_CONSTRAINT_TYPE
UDINT16#731
ERR_CERT_UNSUPPORTED_CONSTRAINT_SYNTAX
UDINT16#732
ERR_CERT_UNSUPPORTED_NAME_SYNTAX
UDINT16#733
ERR_CERT_CRL_PATH_VALIDATION_ERROR
UDINT16#734
ERR_CERT_APPLICATION_VERIFICATION
UDINT16#735
The application is not happy
ERR_CERT_MISSING
UDINT16#736
ERR_CERT_UNKNOWN_ERROR
UDINT16#737
ERR_CERT_UNABLE_TO_GET_ISSUER_CRL
UDINT16#738
UDINT16#B00
Visu redundancy errors
ERR_REDU_MEMORY
UDINT16#B01
ERR_REDU_CLIENT_CREATION_ERR
UDINT16#B02