NextLine (FB)ΒΆ
FUNCTION_BLOCK NextLine EXTENDS CBM.ETrig
Reads the next line of a CSV file.
- InOut:
- Scope - Name - Type - Initial - Comment - Inherited from - Input - xExecute- BOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (- xDone,- xError) are present at the outputs for exactly one cycle.- ETrig - Output - xDone- BOOL- TRUE: Action successfully completed- ETrig - xBusy- BOOL- TRUE: Function block active- ETrig - xError- BOOL- TRUE: Error occurred, function block aborts action- FALSE: No error- ETrig - Input - udiMaxLineLength- UDINT- 255 - Max length of a line - xReset- BOOL- Reset the read position to the first element - psLine- POINTER TO STRING - Pointer the result string - Inout - csvReaderInit- The initialization of CSV reader - Output - eError- Error code - xHasNextLine- BOOL- True, if the reader has more lines. 