UnloadApp (FB)¶
FUNCTION_BLOCK UnloadApp EXTENDS CBML.ETrigATl
This function block implements the command to unload the loaded application of the assigned Safe Control.
The function block is an extension of the Common-Behaviour-Model function block ETrigATl.
- InOut:
Scope
Name
Type
Comment
Inherited from
Input
xExecuteBOOLRising edge: Starts defined operationFALSE: Resets the defined operation after ready condition was reachedETrigATl
xAbortBOOLTRUE: Aborts the operationETrigATl
udiTimeLimitUDINTMax. operating time per invocation [µs], 0: No operating time limit
ETrigATl
Output
xDoneBOOLTRUE: Ready condition reachedETrigATl
xBusyBOOLTRUE: Operation is runningETrigATl
xErrorBOOLTRUE: Error condition reachedETrigATl
xAbortedBOOLTRUE: Abort condition reachedETrigATl
eErrorIDSafeControl_Itf.ERRORError information of fb execution