UnloadApp (FB)

FUNCTION_BLOCK UnloadApp EXTENDS CBML.ETrigATl

This function block implements the command to unload the loaded application of the assigned Safe Control.
The function block is an extension of the Common-Behaviour-Model function block ETrigATl.
InOut:

Scope

Name

Type

Comment

Inherited from

Input

xExecute

BOOL

Rising edge: Starts defined operation
FALSE: Resets the defined operation after ready condition was reached

ETrigATl

xAbort

BOOL

TRUE: Aborts the operation

ETrigATl

udiTimeLimit

UDINT

Max. operating time per invocation [µs], 0: No operating time limit

ETrigATl

Output

xDone

BOOL

TRUE: Ready condition reached

ETrigATl

xBusy

BOOL

TRUE: Operation is running

ETrigATl

xError

BOOL

TRUE: Error condition reached

ETrigATl

xAborted

BOOL

TRUE: Abort condition reached

ETrigATl

eErrorID

SafeControl_Itf.ERROR

Error information of fb execution