SafeApplication (FB)ΒΆ
FUNCTION_BLOCK SafeApplication EXTENDS CBML.LConC
- InOut:
- Scope - Name - Type - Comment - Inherited from - Input - xEnable- BOOL- TRUE: Activates the defined operation- FALSE: Aborts/resets the defined operation- LConC - Output - xBusy- BOOL- TRUE: Operation is running- LConC - xError- BOOL- TRUE: Error condition reached- LConC - eErrorID- SafeControl_Itf.ERROR- Error information of fb execution - AppStatus- SafeControl_Itf.APP_STATE- The application status - AppInfo- SafeControl_Itf.APP_INFO- The application information - BootAppConfirmation- SafeControl_Itf.BOOTAPP_CONFIRMATION- The bootapplication confirmation request (required to confirm the bootapplication start) - xBootAppConfirmationRequested- BOOL- The bootapplication confirmation is request - udnAppCycleExecTimeUS- UDINT- Execution time of application in microseconds - udnAppCycleCount- UDINT- Application cycle counter