CAA_Parameter_Constants (GVL)ΒΆ

Parameter IDs for the PARAMETER struct.

InOut:

Scope

Name

Type

Initial

Comment

Constant

udiPort

UDINT

16#1

DataType=INT | Port number parameter

udiStopBits

UDINT

16#2

DataType=BYTE | Stop bits parameter. See STOPBIT for possible parameter values.

udiParity

UDINT

16#3

DataType=BYTE | Parity parameter. See PARITY for possible parameter values.

udiBaudrate

UDINT

16#4

DataType=DWORD | Baudrate parameter

udiTimeout

UDINT

16#5

DataType=UDINT | Timeout parameter

udiBufferSize

UDINT

16#6

DataType=UDINT | Buffer size parameter, sets the serial buffer size

udiByteSize

UDINT

16#7

DataType=BYTE | Byte size parameter, it sets the number of data bits 4-8

udiBinary

UDINT

16#8

DataType=BOOL | Binary parameter, enables the binary mode

udiOutxCtsFlow

UDINT

16#9

DataType=BOOL | CTS handshaking on output parameter

udiOutxDsrFlow

UDINT

16#A

DataType=BOOL | DSR handshaking on output parameter

udiDtrControl

UDINT

16#B

DataType=BYTE | DTR Flow control parameter. See DTR_CONTROL for possible parameter values.

udiDsrSensitivity

UDINT

16#C

DataType=BOOL | DSR Sensitivity parameter

udiRtsControl

UDINT

16#D

DataType=BYTE | Rts Flow control parameter. See RTS_CONTROL for possible parameter values.

udiTXContinueOnXoff

UDINT

16#E

DataType=BOOL | XOFF continues Tx parameter

udiOutX

UDINT

16#F

DataType=BOOL | XON/XOFF out flow control parameter

udiInX

UDINT

16#10

DataType=BOOL | XON/XOFF in flow control parameter

udiXonChar

UDINT

16#11

DataType=BYTE | Tx AND Rx XON character parameter

udiXoffChar

UDINT

16#12

DataType=BYTE | Tx AND Rx XOFF character parameter

udiXonLim

UDINT

16#13

DataType=WORD | Transmit XON threshold parameter

udiXoffLim

UDINT

16#14

DataType=WORD | Transmit XOFF threshold parameter