Write (FB)¶
FUNCTION_BLOCK Write EXTENDS CBM.ETrigToA
Function block to write data to the serial port
- InOut:
Scope
Name
Type
Comment
Inherited from
Input
xExecuteBOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (xDone,xError) are present at the outputs for exactly one cycle.ETrigToA
xAbortBOOLTRUE: Action is stopped immediately and all outputs are reset to their initial values.ETrigToA
udiTimeOutUDINTDefines the time (µs) after which an FB (e.g. requiring an external acknowledgement) aborts operation due to a timeout with error message.
ETrigToA
Output
xDoneBOOLTRUE: Action successfully completedETrigToA
xBusyBOOLTRUE: Function block activeETrigToA
xErrorBOOLTRUE: Error occurred, function block aborts actionFALSE: No errorETrigToA
xAbortedBOOLTRUE: Action aborted by userETrigToA
Input
hComCAA.HANDLEHandle to the open COM port. Ist returned by the COM.Open function block.
pBufferCAA.PVOIDPointer to a buffer with the data to write to the COM port
szSizeCAA.SIZENumber of bytes in pBuffer to write to the COM port
Output
eErrorLocal library error ID (0: no error; 5001: time out)