LinearTrafo (FB)ΒΆ
FUNCTION_BLOCK LinearTrafo
This function will calculate the linear transformation \(y \in \mathbb{R}\) of \(x \in \mathbb{R}\) according to
\[ \begin{align}\begin{aligned}\frac{y - y_{1}}{y_{2}-y_{1}} = \frac{x-x_{1}}{x_{2}-x_{1}}\\\mathrm{with}\ x_{1}, x_{2}, y_{1}, y_{2} \in \mathbb{R}\ \mathrm{and}\ x_{1} \neq x_{2} \land x_{1} \leq x \leq x_{2}\end{aligned}\end{align} \]
- InOut:
- Scope - Name - Type - Comment - Input - lrInputValue- LREAL- Value \(x\) to be transformated - lrInput1- LREAL- Coefficient \(x_{1} \in \mathbb{R}\) - lrInput2- LREAL- Coefficient \(x_{2} \in \mathbb{R}\) - lrOutput1- LREAL- Coefficient \(y_{1} \in \mathbb{R}\) - lrOutput2- LREAL- Coefficient \(y_{2} \in \mathbb{R}\) - Output - lrOutputValue- LREAL- Linear transformation \(y \in \mathbb{R}\) of \(x \in \mathbb{R}\) - xOutOfLimits- BOOLError flag- TRUE: If \(x_{1} = x_{2} \lor x < x_{1} \lor x > x_2\)