Examples (GVL)¶
Directory¶
(* example of how to use the CAA_FILE-library - directory function blocks *)
PROGRAM DIR_PRG
VAR
    xDirInit:       BOOL := FALSE;
    uiDirState:     UINT := 0;
    sDirNewName:    CAA_FILENAME:='./TestDirectory';
    sDirNextName:   CAA_FILENAME:='./NewDirectory';
    hDir:       CAA_HANDLE;
    deNewDirectory: FILE_DIR_ENTRY;
    fildcr:         FILE.DirCreate;
    fildop:         FILE.DirOpen;
    fildcl:         FILE.DirClose;
    fildls:         FILE.DirList;
    fildrn:         FILE.DirRename;
    fildrm:         FILE.DirRemove;
END_VAR
IF NOT xDirInit THEN
    fildcr(xExecute:=FALSE);
    fildcl(xExecute:=FALSE);
    fildls(xExecute:=FALSE);
    fildrm(xExecute:=FALSE);
    xDirInit:=TRUE;
    uiDirState:=0;
ELSE
    CASE uiDirState OF
    0: (* create a new directory *)
        fildcr.sDirName:=sDirNewName;
        fildcr.xParent:=FALSE;
        fildcr( xExecute:=TRUE);
        IF fildcr.xDone THEN
            uiDirState:=1;
        END_IF
        IF fildcr.xError THEN
            (* error handling*)
            ;
        END_IF
    1: (* open directory     *)
        fildop.sDirName:=sDirNewName;
        fildop( xExecute:=TRUE);
        IF fildop.xDone THEN
            hDir := fildop.hDir;
            uiDirState:=2;
        END_IF
        IF fildop.xError THEN
            (* error handling*)
            ;
        END_IF
    2: (* get directory property list *)
        fildls.hDir:=hDir;
        fildls( xExecute:=TRUE);
        IF fildls.xDone THEN
            deNewDirectory.sEntry :=fildls.deDirEntry.sEntry;
            deNewDirectory.szSize :=fildls.deDirEntry.szSize;
            deNewDirectory.xDirectory :=fildls.deDirEntry.xDirectory;
            deNewDirectory.xExclusive :=fildls.deDirEntry.xExclusive;
            deNewDirectory.dtLastModification :=fildls.deDirEntry.dtLastModification;
            uiDirState:=3;
        END_IF
        IF fildop.xError THEN
            (* error handling*)
            ;
        END_IF
    3: (* close directory *)
        fildcl.hDir:=hDir;
        fildcl( xExecute:=TRUE);
        IF fildcl.xDone THEN
            uiDirState:=4;
        END_IF
        IF fildcl.xError THEN
            (* error handling*)
            ;
        END_IF
    4: (* rename directory*)
        fildrn.sDirNameOld:=sDirNewName;
        fildrn.sDirNameNew:=sDirNextName;
        fildrn( xExecute:=TRUE);
        IF fildrn.xDone THEN
            uiDirState:=5;
        END_IF
        IF fildrn.xError THEN
            (* error handling*)
            ;
        END_IF
    5: (* remove directory*)
        fildrm.sDirName:=sDirNextName;
        fildrm.udiTimeOut:=100000;      (* 100ms TimeOut *)
        fildrm.xRecursive:=FALSE;
        fildrm( xExecute:=TRUE);
        IF fildrm.xDone THEN
            uiDirState:=6;
        END_IF
        IF fildrm.xError THEN
            (* error handling*)
            ;
        END_IF
    6: (* end of example*)
        ;
    END_CASE
END_IF
File - Standard¶
(* example of how to use the CAA_FILE-library - file standard function blocks *)
PROGRAM FILE_STANDARD_PRG
VAR
    xFileStdInit:   BOOL:=FALSE;
    uiFileStdState: UINT:=0;
    sFileName:  CAA_FILENAME:= 'TestFile.txt';
    hFile:      CAA_HANDLE;
    sFileTestString:    STRING:='Hello caa library user';
    sFileString:    STRING:='';
    szFileSize1:    CAA_SIZE := 0;
    szFileSize2:    CAA_SIZE := 0;
    filop:      FILE.Open;
    filwr:      FILE.Write;
    filrd:      FILE.Read;
    filcl:      FILE.Close;
END_VAR
IF NOT xFileStdInit THEN
    filop(xExecute:=FALSE);
    filcl(xExecute:=FALSE);
    filwr(xExecute:=FALSE);
    filrd(xExecute:=FALSE);
    xFileStdInit:=TRUE;
    uiFileStdState:=0;
ELSE
    CASE uiFileStdState OF
    0: (* create a new file *)
        filop.sFileName:=sFileName;
        filop.eFileMode:=FILE_MRDWR;
        filop.xExclusive:=TRUE;
        filop( xExecute:=TRUE);
        IF filop.xDone THEN
            hFile:=filop.hFile;
            uiFileStdState:=1;
        END_IF
        IF filop.xError THEN
            (* error handling*)
            ;
        END_IF
    1:(* write text in the file *)
        filwr.hFile:=hFile;
        filwr.pBuffer:=ADR(sFileTestString);
        szFileSize1:=SIZEOF(sFileTestString);
        filwr.szSize:=szFileSize1;
        filwr.udiTimeOut:=100000;       (* 100ms Timeout *)
        filwr( xExecute:=TRUE);
        IF filwr.xDone THEN
            uiFileStdState:=2;
        END_IF
        IF filwr.xError THEN
            (* error handling*)
            ;
        END_IF
    2:(* read file - TestFile.txt*)
        filrd.hFile:=hFile;
        filrd.udiTimeOut:=100000;       (* 100ms Timeout *)
        filrd.pBuffer:=ADR(sFileString);
        filrd.szBuffer:=255;
        filrd( xExecute:=TRUE);
        IF filrd.xDone THEN
            szFileSize2:=filrd.szSize;
            IF szFileSize2 = szFileSize1 THEN
                uiFileStdState:=3;
            ELSE
                (* error handling*)
                ;
            END_IF
        END_IF
        IF filrd.xError THEN
            (* error handling*)
            ;
        END_IF
    3:  (* close file  - TestFile.txt *)
        filcl.hFile:=hFile;
        filcl( xExecute:=TRUE);
        IF filcl.xDone THEN
            uiFileStdState:=4;
        END_IF
        IF filcl.xError THEN
            (* error handling*)
            ;
        END_IF
    4:  (* end of example *)
                ;
    END_CASE
END_IF
File - Modification¶
(* example of how to use the CAA_FILE-library - file change function blocks *)
PROGRAM FILE_CHANGE_PRG
VAR
    xFileChgInit:   BOOL:=FALSE;
    uiFileChgState: UINT:=0;
    sFileOldName:   CAA_FILENAME:= 'TestFile.txt';
    sFileNewName:   CAA_FILENAME:= 'NewFile.txt';
    szCopiedFileSize:   CAA_SIZE := 0;
    filcp:      FILE.Copy;
    filrn:      FILE.Rename;
    fildl:      FILE.Delete;
END_VAR
IF NOT xFileChgInit THEN
    fildl(xExecute:=FALSE);
    filrn(xExecute:=FALSE);
    filcp(xExecute:=FALSE);
    xFileChgInit:=TRUE;
    uiFileChgState:=0;
ELSE
    CASE uiFileChgState OF
    0:(*copy file *)
        filcp.sFileNameSource:=sFileNewName;
        filcp.sFileNameDest:='DestFile.txt';
        filcp.udiTimeOut:=100000;       (* 100ms Timeout     *)
        filcp.xOverWrite:=TRUE;         (* overwrite the existing file *)
        filcp( xExecute:=TRUE);
        IF filcp.xDone THEN
            szCopiedFileSize := filcp.szSize;
            uiFileChgState:=1;
        END_IF
        IF filcp.xError THEN
            (* error handling*)
            ;
        END_IF
    1: (* rename file *)
        filrn.sFileNameOld:='DestFile.txt';
        filrn.sFileNameNew:=sFileNewName;
        filrn( xExecute:=TRUE);
        IF filrn.xDone THEN
            uiFileChgState:=2;
        END_IF
        IF filrn.xError THEN
            (* error handling*)
            ;
        END_IF
    2:(* delete file *)
        fildl.sFileName:=sFileNewName;
        fildl( xExecute:=TRUE);
        IF fildl.xDone THEN
            uiFileChgState:=3;
        END_IF
        IF fildl.xError THEN
            (* error handling*)
            ;
        END_IF
    3:
    (* end of example*)
        ;
    END_CASE
END_IF
File – internal pointer¶
(* example of how to use the CAA_FILE-library - file position function blocks *)
PROGRAM FILE_POINT_PRG
VAR
    xFilePosInit:       BOOL:=FALSE;
    uiFilePosState:     UINT:=0;
    udiActualPosition:      UDINT:=0;
    udiActualEoFPosition:   UDINT:=0;
    sFileName:      CAA_FILENAME:= 'TestFile.txt';
    hFile:          CAA_HANDLE;
    filop:          FILE.Open;
    filcl:          FILE.Close;
    filgp:          FILE.GetPos;
    filsp:          FILE.SetPos;
    fileof:         FILE.EOF;
END_VAR
IF NOT xFilePosInit THEN
    filop(xExecute:=FALSE);
    filcl(xExecute:=FALSE);
    filgp(xExecute:=FALSE);
    filsp(xExecute:=FALSE);
    fileof(xExecute:=FALSE);
    xFilePosInit:=TRUE;
    uiFilePosState:=0;
ELSE
    CASE uiFilePosState OF
    0:(* open file *)
        filop.sFileName:= sFileName;
        filop.eFileMode:=FILE_MRDWR;
        filop.xExclusive:=TRUE;
        filop( xExecute:=TRUE);
        IF filop.xDone THEN
            hFile:=filop.hFile;
            uiFilePosState:=1;
        END_IF
        IF filop.xError THEN
            (* error handling*)
            ;
        END_IF
    1: (* get actual internal positon file pointer *)
        filgp.hFile:= hFile;
        filgp( xExecute:=TRUE);
        IF filgp.xDone THEN
            udiActualPosition:=filgp.udiPos;
            uiFilePosState:=2;
        END_IF
        IF filgp.xError THEN
            (* error handling*)
            ;
        END_IF
    2:(* query - end of file is reached  *)
        fileof.hFile:= hFile;
        fileof( xExecute:=TRUE);
        IF fileof.xDone THEN
            IF fileof.xEOF THEN
                udiActualEoFPosition:=udiActualPosition;
            END_IF
            uiFilePosState:=3;
        END_IF
        IF filgp.xError THEN
            (* error handling*)
            ;
        END_IF
    3: (* set the internal positon file pointer *)
        filsp.hFile:= hFile;
        filsp.udiPos:=udiActualEoFPosition - 5;
        IF filsp.udiPos < 0 THEN
            filsp.udiPos:=0;
        END_IF
        filsp( xExecute:=TRUE);
        IF filsp.xDone THEN
            uiFilePosState:=4;
        END_IF
        IF filsp.xError THEN
            (* error handling*)
            ;
        END_IF
    4:(* close file *)
        filcl.hFile:=hFile;
        filcl( xExecute:=TRUE);
        IF filcl.xDone THEN
            uiFilePosState:=5;
        END_IF
        IF filcl.xError THEN
            (* error handling*)
            ;
        END_IF
    5: (* end of example*)
        ;
    END_CASE
END_IF
File – Properties¶
(* example of how to use the CAA_FILE-library - file property function blocks *)
PROGRAM FILE_PROP_PRG
VAR
    xFilePropInit:      BOOL:=FALSE;
    uiFilePropState:        UINT:=0;
    sFileName:      CAA_FILENAME:= 'TestFile.txt';
    hFile:          CAA_HANDLE;
    szFileSize:         CAA_SIZE := 0;
    dtLastFileMod:      DT;
    sLastFileModification:  STRING:='';
    filop:          FILE.Open;
    filcl:          FILE.Close;
    filsa:          FILE.SetAttribute;
    filgs:          FILE.GetSize;
    filgt:          FILE.GetTime;
END_VAR
IF NOT xFilePropInit THEN
    filop(xExecute:=FALSE);
    filcl(xExecute:=FALSE);
    filsa(xExecute:=FALSE);
    filgs(xExecute:=FALSE);
    filgt(xExecute:=FALSE);
    xFilePropInit:=TRUE;
    uiFilePropState:=0;
ELSE
    CASE uiFilePropState OF
    0: (* get file size *)
        filgs.sFileName:=sFileName;
        filgs( xExecute:=TRUE);
        IF filgs.xDone THEN
            szFileSize:=filgs.szSize;
            uiFilePropState:=1;
        END_IF
        IF filgs.xError THEN
- Attributes:
- qualified_only
- InOut:
- Scope - Name - Type - Initial - Constant - iDummyforLibDocuCAAFile - INT- 99 