CODESYS GmbH
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
Menu
Search
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
  • BACnetDefaultImpl
    • Function Blocks
      • ApplicationSoftwareVersion (FunctionBlock)
        • Name (Property)
      • AutomaticTimeSync (FunctionBlock)
        • GetTimeZoneFromSystem (Method)
        • Name (Property)
        • TimeZone (Property)
        • Timeout (Property)
        • UpdateTimeZoneFromSystem (Property)
      • BackupRestore (FunctionBlock)
        • BackupFailTime (Property)
        • BackupFilePath (Property)
        • DumpDataBase (Method)
        • GetTimeZoneFromSystem (Method)
        • Name (Property)
        • NumHooks (Property)
        • Password (Property)
        • Restore (Method)
        • RestoreClientCreatedObjects (Property)
        • TimeZone (Property)
        • UpdateTimeZoneFromSystem (Property)
      • ClientCreatableObjects (FunctionBlock)
        • BlockFurtherProcessing (Property)
        • Name (Property)
        • NumHooks (Property)
        • SetMaxNum (Method)
      • DCC_SvcAppHook (FunctionBlock)
        • Name (Property)
        • NumHooks (Property)
        • Password (Property)
      • DevelopmentSupport
      • DeviceDateTime (FunctionBlock)
        • GetTimeZoneFromSystem (Method)
        • Name (Property)
        • RegisterTimeProvider (Method)
        • TimeZone (Property)
        • UnregisterTimeProvider (Method)
        • UpdateTimeZoneFromSystem (Property)
      • LimitDeviceObjectPropertyReferencesToCertainTypes (FunctionBlock)
        • GetCallback (Method)
        • GetHook (Method)
        • Name (Property)
        • NumCallbacks (Property)
        • NumHooks (Property)
      • LoggingObjects
        • Internal
        • TrendLog (FunctionBlock)
      • NetworkPortObjects (FunctionBlock)
        • Connect (Method)
        • Name (Property)
        • SetDNSserverToGateway (Property)
      • ObjectPersistence (FunctionBlock)
        • DeleteAllData (Method)
        • DumpDataBase (Method)
        • HardShutdown (Property)
        • LogIndexFileContent (Method)
        • Name (Property)
        • PersistentPath (Property)
        • RestoreClientCreatedObjects (Property)
      • PropertyConfiguration (Folder)
        • DoGetPropertyAttributes (Method)
        • GetPropertyAttributes (Method)
        • Logging
        • Name (Property)
      • PropertyConfigurationMostlyAllPersistent (FunctionBlock)
        • GetPropertyAttributes (Method)
        • Name (Property)
      • PropertyConfigurationMostlyAllWritable (FunctionBlock)
        • GetPropertyAttributes (Method)
        • Name (Property)
      • ReinitDevice_SvcAppHook (FunctionBlock)
        • GetTimeZoneFromSystem (Method)
        • Name (Property)
        • NumHooks (Property)
        • Password (Property)
        • TimeZone (Property)
        • UpdateTimeZoneFromSystem (Property)
      • TimeSync_SvcAppHook (FunctionBlock)
        • GetTimeZoneFromSystem (Method)
        • Name (Property)
        • NumHooks (Property)
        • TimeZone (Property)
        • UpdateTimeZoneFromSystem (Property)
      • UTCTimeSync_SvcAppHook (FunctionBlock)
        • BACnetEventCallback (Method)
        • GetHook (Method)
        • Init (Method)
        • Name (Property)
        • NumHooks (Property)
      • UnconfiguredDeviceDiscoveryAndAddressAssignment (FunctionBlock)
        • Name (Property)
        • NumHooks (Property)
    • Functions
      • DATETIME_TO_RTS_SYSTIMEDATE (Function)
      • DateTimeToString (Function)
      • DateTimeToTimestamp (Function)
      • Directory (FunctionBlock)
        • Close (Method)
        • GetDir (Method)
        • Read (Method)
        • SetDir (Method)
        • ls_log (Method)
      • GetLocalTime (Function)
      • GetSystemTimeZone (Function)
      • PersistenceWriteProperty (Function)
      • PropAddrString (Function)
      • PropertyContentToString (Function)
      • RTS_SYSTIMEDATE_TO_STRING (Function)
      • SysTimeDateToString (Function)
      • Time2BACnetDateTime (Function)
      • Time2BACnetTimeStamp (Function)
      • TimeZoneSegmentToString (Function)
      • TimeZoneToString (Function)
      • TimezoneInformationToString (Function)
      • UtilDateTimeToString (Function)
    • GlobalConstants
      • Constants (GVL)
    • Structs
      • PERSISTENT_PDATA_HEADER (Struct)
      • Persistence
        • PERSISTENT_DATA_BUFFER (Struct)
        • PERSISTENT_INDEX_HEADER (Struct)
        • PERSISTENT_PDATA_ENTRY (Struct)
      • PropertyConfiguration
        • PropertyConfigurationObjectPropertyPair (Struct)
    • Types
      • FileNameString (Alias)
  • Library Information
    • GetLibVersion (Function)
    • GetLibVersionNumber (Function)
    • IsLibReleased (Function)
  • File and Project Information
  • Library Reference
    • BACnet2
      • Library Identification
      • Library Properties
    • CmpBACnet2
      • Library Identification
      • Library Properties
    • CmpErrors2 Interfaces
      • Library Identification
      • Library Properties
    • CmpEventMgr
      • Library Identification
      • Library Properties
    • CmpLog
      • Library Identification
      • Library Properties
    • Component Manager
      • Library Identification
      • Library Properties
    • Standard
      • Library Identification
      • Library Properties
    • StringUtils
      • Library Identification
      • Library Properties
    • SysDir
      • Library Identification
      • Library Properties
    • SysFile
      • Library Identification
      • Library Properties
    • SysMem
      • Library Identification
      • Library Properties
    • SysSem
      • Library Identification
      • Library Properties
    • SysTime
      • Library Identification
      • Library Properties
    • SysTypes2 Interfaces
      • Library Identification
      • Library Properties
    • Util
      • Library Identification
      • Library Properties
      • Library Parameter
BACnet2DefaultImpl
  • Docs »
  • BACnetDefaultImpl »
  • Structs »
  • PropertyConfiguration

PropertyConfigurationΒΆ

  • PropertyConfigurationObjectPropertyPair (Struct)
top

CODESYS Group | We software Automation. to software
['sɒftwɛər]
transitive verb
__softwared/softwaring
: to develop software
// to software automation: to develop software for automation purposes

The CODESYS Group is the manufacturer of CODESYS, the leading hardware-independent IEC 61131-3 automation software for developing and engineering controller applications.
CODESYS® is a registered trademark.

CODESYS GmbH
A member of the CODESYS Group
Memminger Straße 151, 87439 Kempten
Germany
Tel.: +49-831-54031-0
info@codesys.com
  • Legal Notice
  • Privacy Policy
LinkedIn Youtube RSS Downloads Login CODESYS Store
© 2022 CODESYS GmbH | A member of the CODESYS Group