BACnetLifeSafetyPoint (FB)ΒΆ

FUNCTION_BLOCK PUBLIC BACnetLifeSafetyPoint EXTENDS BACnetStaticObjectBase

FB reflecting a BACnet-LifeSafetyPoint-Object. All Properties of this FB give access to the client writeable BACnet-Properties of the reflected BACnet-Object, although the access is done not client sided (without checking access restrictions). Additionaly access is given for the Present_Value-Property, although the latter is not (always) client side writeable. Moreover access right behaviour which changes due to dynamically changing BACnet-Property-Sets is done by an Event-Callback (BACnetEventCallback), which is attached to the BACNET_CALLBACK_WRITE-Callback. Additionally see documentation of BACnetObjectBase.

Properties:

Methods:

GetBACnetAccumulatorRecordProperty, inherited from BACnetObjectBase

GetBACnetArraySizeOfProperty, inherited from BACnetObjectBase

GetBACnetBitStringProperty, inherited from BACnetObjectBase

GetBACnetBooleanProperty, inherited from BACnetObjectBase

GetBACnetClientCOVProperty, inherited from BACnetObjectBase

GetBACnetColorCommandProperty, inherited from BACnetObjectBase

GetBACnetDateProperty, inherited from BACnetObjectBase

GetBACnetDateRangeProperty, inherited from BACnetObjectBase

GetBACnetDateTime2Property, inherited from BACnetObjectBase

GetBACnetDateTimeProperty, inherited from BACnetObjectBase

GetBACnetDevObjPropReferenceProperty, inherited from BACnetObjectBase

GetBACnetDevObjReferenceProperty, inherited from BACnetObjectBase

GetBACnetDoubleProperty, inherited from BACnetObjectBase

GetBACnetEnumeratedProperty, inherited from BACnetObjectBase

GetBACnetLightingCommandProperty, inherited from BACnetObjectBase

GetBACnetObjPropReferenceProperty, inherited from BACnetObjectBase

GetBACnetObjectIDProperty, inherited from BACnetObjectBase

GetBACnetOptionalEnumeratedProperty, inherited from BACnetObjectBase

GetBACnetOptionalPriorityFilterProperty, inherited from BACnetObjectBase

GetBACnetOptionalREALProperty, inherited from BACnetObjectBase

GetBACnetOptionalUnsignedProperty, inherited from BACnetObjectBase

GetBACnetPrescaleProperty, inherited from BACnetObjectBase

GetBACnetProcessIdSelectionProperty, inherited from BACnetObjectBase

GetBACnetRealProperty, inherited from BACnetObjectBase

GetBACnetRecipientProperty, inherited from BACnetObjectBase

GetBACnetScaleProperty, inherited from BACnetObjectBase

GetBACnetSetpointReferenceProperty, inherited from BACnetObjectBase

GetBACnetShedLevelProperty, inherited from BACnetObjectBase

GetBACnetSignedProperty, inherited from BACnetObjectBase

GetBACnetStringProperty, inherited from BACnetObjectBase

GetBACnetTime2Property, inherited from BACnetObjectBase

GetBACnetTimeProperty, inherited from BACnetObjectBase

GetBACnetTimeStampProperty, inherited from BACnetObjectBase

GetBACnetUnsignedProperty, inherited from BACnetObjectBase

GetBACnetValueSourceProperty, inherited from BACnetObjectBase

GetBACnetxyColorProperty, inherited from BACnetObjectBase

GetPropertyAccessRight, inherited from BACnetObjectBase

GetPropertyCallbackAttachment, inherited from BACnetObjectBase

GetPropertyId, inherited from BACnetObjectBase

GetPropertyInstanceStackAllocContentBuffer, inherited from BACnetObjectBase

GetPropertyInstanceWithContentBuffer, inherited from BACnetObjectBase

Initialize

IsBACnetDateTimePropertyUnspecified, inherited from BACnetObjectBase

IsPropertyExistent, inherited from BACnetObjectBase

IsPropertyWriteable, inherited from BACnetObjectBase

SetBACnetAccumulatorRecordProperty, inherited from BACnetObjectBase

SetBACnetArraySizeOfProperty, inherited from BACnetObjectBase

SetBACnetBitStringProperty, inherited from BACnetObjectBase

SetBACnetBooleanProperty, inherited from BACnetObjectBase

SetBACnetClientCOVProperty, inherited from BACnetObjectBase

SetBACnetColorCommandProperty, inherited from BACnetObjectBase

SetBACnetDateProperty, inherited from BACnetObjectBase

SetBACnetDateRangeProperty, inherited from BACnetObjectBase

SetBACnetDateTime2Property, inherited from BACnetObjectBase

SetBACnetDateTimeProperty, inherited from BACnetObjectBase

SetBACnetDateTimePropertyToUnspecified, inherited from BACnetObjectBase

SetBACnetDevObjPropReferenceProperty, inherited from BACnetObjectBase

SetBACnetDevObjReferenceProperty, inherited from BACnetObjectBase

SetBACnetDoubleProperty, inherited from BACnetObjectBase

SetBACnetEnumeratedProperty, inherited from BACnetObjectBase

SetBACnetLightingCommandProperty, inherited from BACnetObjectBase

SetBACnetObjPropReferenceProperty, inherited from BACnetObjectBase

SetBACnetObjectIDProperty, inherited from BACnetObjectBase

SetBACnetOctetStringProperty, inherited from BACnetObjectBase

SetBACnetOptionalEnumeratedProperty, inherited from BACnetObjectBase

SetBACnetOptionalPriorityFilterProperty, inherited from BACnetObjectBase

SetBACnetOptionalREALProperty, inherited from BACnetObjectBase

SetBACnetOptionalUnsignedProperty, inherited from BACnetObjectBase

SetBACnetPrescaleProperty, inherited from BACnetObjectBase

SetBACnetProcessIdSelectionProperty, inherited from BACnetObjectBase

SetBACnetRealProperty, inherited from BACnetObjectBase

SetBACnetRecipientProperty, inherited from BACnetObjectBase

SetBACnetScaleProperty, inherited from BACnetObjectBase

SetBACnetSetpointReferenceProperty, inherited from BACnetObjectBase

SetBACnetShedLevelProperty, inherited from BACnetObjectBase

SetBACnetSignedProperty, inherited from BACnetObjectBase

SetBACnetStringProperty, inherited from BACnetObjectBase

SetBACnetTime2Property, inherited from BACnetObjectBase

SetBACnetTimeProperty, inherited from BACnetObjectBase

SetBACnetTimeStampProperty, inherited from BACnetObjectBase

SetBACnetUnsignedProperty, inherited from BACnetObjectBase

SetBACnetValueSourceProperty, inherited from BACnetObjectBase

SetBACnetxyColorProperty, inherited from BACnetObjectBase

SetObjectName, inherited from BACnetObjectBase

SetPropertyAccessRight, inherited from BACnetObjectBase

SetPropertyCallbackAttachment, inherited from BACnetObjectBase

SetPropertyInstance, inherited from BACnetObjectBase

WritePropertyInstance, inherited from BACnetObjectBase

Structure: