UpdateDeviceTwin (FB)¶
FUNCTION_BLOCK UpdateDeviceTwin EXTENDS CBM.ETrigTo
Update the device twin (desired properties only!) via HTTPS.
- InOut:
- Scope - Name - Type - Comment - Inherited from - Input - xExecute- BOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (- xDone,- xError) are present at the outputs for exactly one cycle.- ETrigTo - udiTimeOut- UDINT- Defines the time (µs) after which an FB (e.g. requiring an external acknowledgement) aborts operation due to a timeout with error message. - ETrigTo - Output - xDone- BOOL- TRUE: Action successfully completed- ETrigTo - xBusy- BOOL- TRUE: Function block active- ETrigTo - xError- BOOL- TRUE: Error occurred, function block aborts action- FALSE: No error- ETrigTo - Input - sHubDomainName- STRING(255)- Domain name of the IoT Hub - sDeviceId- STRING(255)- Device ID - wsSaS- WSTRING(255)- Shared Access Signature (SAS Token) - pwsData- POINTER TO WSTRING - The device twin properties to update (Input, JSON format) - Output - eError- Error code - iHttpStatus- INT- HTTP status - wsDeviceTwinInfo- WSTRING(WEB_CLIENT.g_udiMaxResponseSize)- Last device twin info (Output, JSON format) 
