CODESYS GmbH
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
Menu
Search
  • Deutsch
  • English
  • Français
  • Español
  • Italiano
  • Русский
  • 日本語
  • 中文
  • ALARMGROUP_ID (Alias)
  • ALARM_ID (Alias)
  • Access to alarm storage (internal)
    • IAlarmStorageDataComparer
      • CommentComparer (FunctionBlock)
        • Compare (Method)
      • UserIdComparer (FunctionBlock)
        • Compare (Method)
    • IDatabaseAccess
      • IDatabaseAccess4 (Interface)
        • TblAlarmGetCommentValue (Method)
    • only internal
      • GetLatchVarColumnID (Function)
  • Alarm storage API
    • AlarmStorageConvertFromTimestamp (Function)
    • AlarmStorageConvertToTimestamp (Function)
    • AlarmStorageConvertValueToLREAL (Function)
    • AlarmStorageConvertValueToREAL (Function)
    • AlarmStorageConvertValueToString (Function)
    • AlarmStorageGetDefaultText (Function)
    • AlarmStorageGetMessageCount (Function)
    • AlarmStorageGetTextId (Function)
    • AlarmStorageGetTextListName (Function)
    • AlarmStorageReader (FunctionBlock)
      • AddAlarmStorageListener (Method)
      • ContinueReading (Method)
      • FB_Init (Method)
      • GetFirstLastRowID (Method)
      • GetMinMaxTimestamps (Method)
      • Read (Method)
      • RemoveAlarmStorageListener (Method)
      • SemaphoreAcquire (Method)
      • SemaphoreRelease (Method)
      • private
        • prvReadAlarmComment (Method)
        • prvReadLatchVarString (Method)
        • prvReadLatchVarString2 (Method)
        • prvRetrieveLatchVarValue (Method)
        • prvTblAlarmFindTimestamp (Method)
    • AlarmStorageReaderGlobals (GVL)
    • AlarmStorageRow (FunctionBlock)
      • GetLatchVarValue (Method)
      • ResetAlarmComments (Method)
      • SetLatchVarValue (Method)
    • AlarmStorageStaticData (Struct)
    • EAlarmComment (Enum)
    • EAlarmStorageReaderErrors (Enum)
    • IAlarmStorageListener (Interface)
      • AlarmAdded (Method)
      • AlarmModified (Method)
    • IAlarmStorageReaderConsumer (Interface)
      • AlarmRead (Method)
      • BeforeReading (Method)
      • LatchVariableRead (Method)
      • ReadingDataCompleted (Method)
    • IAlarmStorageReaderConsumer2 (Interface)
      • ByteOrder (Property)
  • AlarmEvaluation_Prg (Program)
  • AlarmStorage_Prg (Program)
  • Enumerations
    • AlarmState (Enum)
    • AlarmStateTransition (Enum)
    • EAlarmType (Enum)
    • EDBActiveIndex (Enum)
    • EDBType (Enum)
    • EFilterLatchContent (Enum)
    • EFilterTimeRangeType (Enum)
  • Function blocks
    • DatabaseSizeLimit (FunctionBlock)
      • CheckForSizeLimit (Method)
      • IDatabaseSizeLimit
        • LastReorderingTime (Property)
        • ReorderingCount (Property)
      • Initialize (Method)
      • IsBlocked (Property)
    • DefaultAlarmFilterCriteria (FunctionBlock)
    • Utilities
      • AlarmCommentHelper (FunctionBlock)
        • CopyWStringToAlarmComment (Method)
        • FreeAlarmComment (Method)
      • AlarmEvaluator (FunctionBlock)
        • prvPreprocessAlarmActivation (Method)
        • prvPreprocessEventActivation (Method)
        • prvProcessAcknowledgement (Method)
        • prvProcessHigherPriorityAlarm (Method)
      • AlarmStorageLimit (FunctionBlock)
        • Active (Property)
        • Decrement (Method)
        • Increment (Method)
        • SetLimit (Method)
      • IsStateWaitingForConfirmation (Function)
      • TextHelper (FunctionBlock)
        • FB_Exit (Method)
        • FromString (Method)
        • FromWString (Method)
  • Functions
    • AlarmIsIntervalElapsed (Function)
    • CheckNotifiableTransitionOfAlarm (Function)
    • ConvertTimestampToLDateAndTime (Function)
    • DT_to_Timestamp (Function)
    • DT_to_Timestamp2 (Function)
    • Filters
      • ElaborateLatchFilterCriteria (Function)
      • ElaborateTimeRangeFilterCriteria (Function)
    • FormatCommentValue (Function)
    • FormatTimestamp2 (Function)
    • FormatTypedValue (Function)
    • GetAlarmIDName (Function)
    • GetDatabaseFileSize (Function)
    • GetDatabaseFileSize2 (Function)
    • GetLINTValue (Function)
    • GetLINTValue2 (Function)
    • GetLINTValue3 (Function)
    • GetPStringValue (Function)
    • GetPWStringValue (Function)
    • HasAlarmStorageRecordLimit (Function)
    • MonitorPopulateFilterCriteria (Function)
    • SplitString (Function)
    • Swap
      • SwapDword (Function)
      • SwapLword (Function)
      • SwapWord (Function)
    • Timestamp_to_DT (Function)
    • deprecated
      • FormatTimestamp (Function)
  • GetBooleanProperty (Function)
  • GetCompany (Function)
  • GetNumberProperty (Function)
  • GetTextProperty (Function)
  • GetTitle (Function)
  • GetVersion (Function)
  • GetVersionProperty (Function)
  • Globals
    • AlarmGlobals (GVL)
    • AlarmParams (ParamList)
    • AlarmTestConstants (GVL)
    • ReturnValues (GVL)
  • Interfaces
    • IAlarm (Interface)
      • Access-to-timestamps
        • GetTimestampAcknowledge (Method)
        • GetTimestampActive (Method)
        • GetTimestampInactive (Method)
        • GetTimestampLast (Method)
      • Access-to-values
        • GetCurrentValue (Method)
        • GetLatchVar1Value (Method)
        • GetLatchVar2Value (Method)
        • GetTriggerValue (Method)
      • GetAlarmClass (Method)
      • GetAlarmGroup (Method)
      • GetID (Method)
      • GetInternalID (Method)
      • GetMessage (Method)
      • GetState (Method)
      • IsDeactivated (Method)
    • IAlarm2 (Interface)
    • IAlarm3 (Interface)
      • GetCountLatchVariables (Method)
      • GetCountMessages (Method)
      • GetLatchVarValue (Method)
      • GetMessage2 (Method)
      • SetLatchVarValue (Method)
    • IAlarm4 (Interface)
      • KindOf (Property)
    • IAlarm5 (Interface)
      • Access-to-offsets
        • OffsetAcknowledge (Property)
        • OffsetActive (Property)
        • OffsetInactive (Property)
        • OffsetLast (Property)
    • IAlarm6 (Interface)
      • AlarmGroupTemplate (Property)
    • IAlarm7 (Interface)
      • CommentActive (Property)
      • CommentActiveAck (Property)
      • CommentNormal (Property)
      • CommentWaitingConf (Property)
      • ReAlarmRepeatCount (Property)
      • UserIdCommentActive (Property)
      • UserIdCommentActiveAck (Property)
      • UserIdCommentNormal (Property)
      • UserIdCommentWaitingConf (Property)
    • IAlarmClass (Interface)
      • GetInternalID (Method)
      • GetName (Method)
      • GetPriority (Method)
      • IsAcknowledgeSeparately (Method)
    • IAlarmClass2 (Interface)
      • AckInsteadOfConfirm (Method)
      • AutoResetDigitalAlarms (Method)
      • ReAlarmTime (Property)
    • IAlarmConfiguration7 (Interface)
      • ClearHistory (Method)
    • IAlarmConfiguration8 (Interface)
      • DatabaseSizeLimit (Property)
    • IAlarmGroup (Interface)
      • GetInternalID (Method)
      • GetName (Method)
    • IAlarmGroup3 (Interface)
      • GetID (Method)
    • IAlarmHandler (Interface)
      • AcknowledgeAll (Method)
      • AcknowledgeAllOfGroup (Method)
      • AcknowledgeOneOfGroup (Method)
      • RaiseEvent (Method)
    • IAlarmHandler2 (Interface)
      • GetActiveAlarms (Method)
      • GetAlarmsFromStorage (Method)
      • GetCountAlarmsFromStorage (Method)
      • RegisterClient (Method)
      • UnregisterClient (Method)
    • IAlarmHandler3 (Interface)
    • IAlarmHandler4 (Interface)
      • RegisterAlarmStateChangedListener (Method)
    • IAlarmHandler5 (Interface)
      • AlarmConfigurationCount (Property)
      • GetAlarmConfiguration (Method)
    • IAlarmHandler6 (Interface)
      • AcknowledgeAllOfGroupWithComment (Method)
      • AcknowledgeAllWithComment (Method)
      • AcknowledgeOneOfGroupWithComment (Method)
      • SetComment (Method)
    • IAlarmHandlerRemoteMonitor (Interface)
      • GetProxyAlarmClassesDescription (Method)
      • GetProxyAlarmGroupsDescription (Method)
      • GetProxyAlarmsDescription (Method)
      • GetProxyStatistics (Method)
      • GetProxyStatisticsSingleActivity (Method)
    • IAlarmManagerClient (Interface)
      • ActiveAlarmsChanged (Method)
      • AlarmStorageModified (Method)
      • GetFilterCriteria (Method)
    • IAlarmManagerClient2 (Interface)
      • EventOccurred (Method)
    • IAlarmNotifiable (Interface)
      • Execute (Method)
    • IAlarmRemote (Interface)
      • RemoteDeviceName (Property)
    • IAlarmStateChangedEventListener (Interface)
      • ActionStateChanged (Method)
      • DeactivationStateChanged (Method)
      • RegisterListener (Method)
    • IAlarmStateChangedListener (Interface)
      • AlarmStateChanged (Method)
    • IAlarmStateChangedListener2 (Interface)
      • AlarmDeactivationStateChanged (Method)
    • IDatabaseFileAlarmStorage8 (Interface)
      • SetEmptyTimestampInactiveToStartTime (Method)
    • IDatabaseFileAlarmStorage9 (Interface)
      • CheckFileLimitReachedUDINT (Method)
      • CheckRecordLimitReachedUDINT (Method)
      • SetEmptyTimestampInactiveToStartTime (Method)
    • IResetValueProvider (Interface)
      • ResetValue (Method)
  • Optimized placeholder replacement
    • AlarmLatchAdapter (FunctionBlock)
      • FB_Init (Method)
      • GetCountLatchVariables (Method)
      • GetLatchVarValue (Method)
      • Initialize (Method)
      • SetLatchVarValue (Method)
  • Project Information
    • GetTextProperty2 (Function)
  • Proxy
    • IProxyMonitor (Interface)
      • GetAlarmClassesDescription (Method)
      • GetAlarmGroupsDescription (Method)
      • GetAlarmsDescription (Method)
      • GetStatistics (Method)
      • GetStatisticsSingleReq (Method)
    • ProxyEnumState (Enum)
    • ProxyFbHistActiveAlarmsQueue (FunctionBlock)
      • EffectiveRead (Property)
      • FB_Exit (Method)
      • GetActiveCount (Method)
      • GetAvailableEntries (Method)
      • GetLastState (Method)
      • GetRowIDActive (Method)
      • GetRowIDLocal (Method)
      • Initialize (Method)
      • Insert (Method)
      • IsPresentRowIDRemote (Method)
      • QueueSize (Property)
      • Remove (Method)
      • SetLastState (Method)
    • ProxyFbHistAlarmsRowQueue (FunctionBlock)
      • FB_Exit (Method)
      • GetAvailableEntries (Method)
      • GetCountToRegister (Method)
      • GetItem (Method)
      • Initialize (Method)
      • MaxEntries (Property)
    • ProxyGVL (GVL)
    • Statistics_LTIME (FunctionBlock)
      • Average (Property)
      • Count (Property)
      • Maximum (Property)
      • Minimum (Property)
    • Structures
      • Monitor
        • ProxyStructMonitor (Struct)
        • ProxyStructMonitorAlarmClassDesc (Struct)
        • ProxyStructMonitorAlarmDesc (Struct)
        • ProxyStructMonitorAlarmGroupDesc (Struct)
        • ProxyStructMonitorRequest (Struct)
      • ProxyStructError (Struct)
  • Service
    • AlarmFctWriteLatchVariable (Function)
    • AlarmIndices (Struct)
    • AlarmStorageLatchVariable (Struct)
    • HistoricalActiveAlarmRowID (Struct)
  • Structures
    • LatchVariable (Struct)
    • MonitorDBStatus (Struct)
    • MonitorFilterByDateTime (Struct)
    • MonitorFilterByLatch (Struct)
    • StorageTaskInfo (Struct)
  • TIMESTAMP (Alias)
  • TL_AlarmStatus (TextList)
  • File and Project Information
  • Library Reference
    • 3S Storage
      • Library Identification
      • Library Properties
    • Alarm Manager Interfaces
      • Library Identification
      • Library Properties
    • Alarm Manager Internal Interfaces
      • Library Identification
      • Library Properties
    • Base Interfaces
      • Library Identification
      • Library Properties
    • CAA Storage
      • Library Identification
      • Library Properties
    • CAA Types Extern
      • Library Identification
      • Library Properties
    • CDSV3ProtocolUtils
      • Library Identification
      • Library Properties
    • CmpApp
      • Library Identification
      • Library Properties
    • CmpBinTagUtilIec
      • Library Identification
      • Library Properties
    • CmpDynamicText
      • Library Identification
      • Library Properties
    • CmpErrors2 Interfaces
      • Library Identification
      • Library Properties
    • CmpEventMgr
      • Library Identification
      • Library Properties
    • CmpIecTask
      • Library Identification
      • Library Properties
    • CmpLog
      • Library Identification
      • Library Properties
    • CmpSrv
      • Library Identification
      • Library Properties
    • CmpVisuHandler
      • Library Identification
      • Library Properties
    • Collections
      • Library Identification
      • Library Properties
    • Component Manager
      • Library Identification
      • Library Properties
    • Datasources Interfaces
      • Library Identification
      • Library Properties
    • Element Collections
      • Library Identification
      • Library Properties
    • Standard
      • Library Identification
      • Library Properties
    • StringUtils
      • Library Identification
      • Library Properties
    • SysCpuHandling
      • Library Identification
      • Library Properties
    • SysFile
      • Library Identification
      • Library Properties
    • SysMem
      • Library Identification
      • Library Properties
    • SysProcess
      • Library Identification
      • Library Properties
    • SysSem
      • Library Identification
      • Library Properties
    • SysTask
      • Library Identification
      • Library Properties
    • SysTimeCore
      • Library Identification
      • Library Properties
    • SysTimeRtc
      • Library Identification
      • Library Properties
    • SysTypes2 Interfaces
      • Library Identification
      • Library Properties
    • VisuShared
      • Library Identification
      • Library Properties
AlarmManager
  • Docs »
  • Interfaces »
  • IAlarmHandler6 (ITF)

IAlarmHandler6 (ITF)ΒΆ

INTERFACE IAlarmHandler6 EXTENDS IAlarmHandler5

Properties:

AlarmConfigurationCount, inherited from IAlarmHandler5

Methods:

AcknowledgeAllOfGroupWithComment

AcknowledgeAllWithComment

AcknowledgeOneOfGroupWithComment

SetComment

AcknowledgeAll, inherited from IAlarmHandler

AcknowledgeAllOfGroup, inherited from IAlarmHandler

AcknowledgeOneOfGroup, inherited from IAlarmHandler

GetActiveAlarms, inherited from IAlarmHandler2

GetAlarmConfiguration, inherited from IAlarmHandler5

GetAlarmsFromStorage, inherited from IAlarmHandler2

GetCountAlarmsFromStorage, inherited from IAlarmHandler2

RaiseEvent, inherited from IAlarmHandler

RegisterAlarmStateChangedListener, inherited from IAlarmHandler4

RegisterClient, inherited from IAlarmHandler2

UnregisterClient, inherited from IAlarmHandler2

Structure:

  • AcknowledgeAllOfGroupWithComment (Method)
  • AcknowledgeAllWithComment (Method)
  • AcknowledgeOneOfGroupWithComment (Method)
  • SetComment (Method)
top

CODESYS Group | We software Automation. to software
['sɒftwɛər]
transitive verb
__softwared/softwaring
: to develop software
// to software automation: to develop software for automation purposes

The CODESYS Group is the manufacturer of CODESYS, the leading hardware-independent IEC 61131-3 automation software for developing and engineering controller applications.
CODESYS® is a registered trademark.

CODESYS GmbH
A member of the CODESYS Group
Memminger Straße 151, 87439 Kempten
Germany
Tel.: +49-831-54031-0
info@codesys.com
  • Legal Notice
  • Privacy Policy
LinkedIn Youtube RSS Downloads Login CODESYS Store
© 2022 CODESYS GmbH | A member of the CODESYS Group