3S Storage

Library Identification

Placeholder: CAA Storage Imp
Default Resolution: 3S Storage, * (3S - Smart Software Solutions GmbH)
Namespace: STI

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CAA Storage Imp

Alarm Manager Interfaces

Library Identification

Name: Alarm Manager Interfaces
Version: newest
Company: Intern
Namespace: AlarmManager_Interfaces

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Alarm Manager Interfaces, * (Intern)

Alarm Manager Internal Interfaces

Library Identification

Name: Alarm Manager Internal Interfaces
Version: newest
Company: Intern
Namespace: AlarmManagerInternal_Interfaces

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Alarm Manager Internal Interfaces, * (Intern)

Base Interfaces

Library Identification

Name: Base Interfaces
Version: newest
Company: System
Namespace: IBaseLibrary

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Base Interfaces, * (System)

CAA Storage

Library Identification

Placeholder: CAA Storage
Default Resolution: CAA Storage, * (CAA Technical Workgroup)
Namespace: STO

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CAA Storage

CAA Types Extern

Library Identification

Placeholder: CAA Types
Default Resolution: CAA Types Extern, * (CAA Technical Workgroup)
Namespace: CAA

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CAA Types

CDSV3ProtocolUtils

Library Identification

Placeholder: CDSV3ProtocolUtils
Default Resolution: CDSV3ProtocolUtils, * (3S - Smart Software Solutions GmbH)
Namespace: CDSV3Prot

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CDSV3ProtocolUtils

CmpApp

Library Identification

Placeholder: CmpApp
Default Resolution: CmpApp, * (System)
Namespace: CmpApp

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpApp

CmpBinTagUtilIec

Library Identification

Placeholder: CmpBinTagUtilIec
Default Resolution: CmpBinTagUtilIec, * (System)
Namespace: CmpBinTagUtilIec

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpBinTagUtilIec

CmpDynamicText

Library Identification

Placeholder: CmpDynamicText
Default Resolution: CmpDynamicText, * (System)
Namespace: CmpDynamicText

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpDynamicText

CmpErrors2 Interfaces

Library Identification

Name: CmpErrors2 Interfaces
Version: newest
Company: System
Namespace: CmpErrors

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpErrors2 Interfaces, * (System)

CmpEventMgr

Library Identification

Placeholder: CmpEventMgr
Default Resolution: CmpEventMgr, * (System)
Namespace: CmpEventMgr

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpEventMgr

CmpLog

Library Identification

Placeholder: CmpLog
Default Resolution: CmpLog, * (System)
Namespace: CmpLog

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpLog

CmpSrv

Library Identification

Placeholder: CmpSrv
Default Resolution: CmpSrv, * (System)
Namespace: CmpSrv

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpSrv

CmpVisuHandler

Library Identification

Placeholder: CmpVisuHandler
Default Resolution: CmpVisuHandler, * (System)
Namespace: CmpVisuHandler

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpVisuHandler

Collections

Library Identification

Placeholder: Collections
Default Resolution: Collections, * (System)
Namespace: Collections

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Collections

Component Manager

Library Identification

Placeholder: Component Manager
Default Resolution: Component Manager, * (System)
Namespace: Component_Manager

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Component Manager

Datasources Interfaces

Library Identification

Name: Datasources Interfaces
Version: newest
Company: 3S - Smart Software Solutions GmbH
Namespace: IDatasources

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: Datasources Interfaces, * (3S - Smart Software Solutions GmbH)

Element Collections

Library Identification

Placeholder: ElementCollections
Default Resolution: Element Collections, * (3S - Smart Software Solutions GmbH)
Namespace: COL

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: ElementCollections

Standard

Library Identification

Placeholder: Standard
Default Resolution: Standard, * (System)
Namespace: Standard

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Standard

StringUtils

Library Identification

Placeholder: StringUtils
Default Resolution: StringUtils, * (System)
Namespace: Stu

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: StringUtils

SysFile

Library Identification

Placeholder: SysFile
Default Resolution: SysFile, * (System)
Namespace: SysFile

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysFile

SysMem

Library Identification

Placeholder: SysMem
Default Resolution: SysMem, * (System)
Namespace: SysMem

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysMem

SysProcess

Library Identification

Placeholder: SysProcess
Default Resolution: SysProcess, * (System)
Namespace: SysProcess

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysProcess

SysSem

Library Identification

Placeholder: SysSem
Default Resolution: SysSem, * (System)
Namespace: SysSem

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysSem

SysTask

Library Identification

Placeholder: SysTask
Default Resolution: SysTask, * (System)
Namespace: SysTask

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTask

SysTimeCore

Library Identification

Placeholder: SysTimeCore
Default Resolution: SysTimeCore, * (System)
Namespace: SysTimeCore

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTimeCore

SysTimeRtc

Library Identification

Placeholder: SysTimeRtc
Default Resolution: SysTimeRtc, * (System)
Namespace: SysTimeRtc

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTimeRtc

SysTypes2 Interfaces

Library Identification

Name: SysTypes2 Interfaces
Version: newest
Company: System
Namespace: SysTypes

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTypes2 Interfaces, * (System)