• AC_Module
    • BaseInstance (FunctionBlock)
      • ComAddress (Property)
      • FB_EXIT (Method)
      • Init (Method)
      • InitParametersDone (Property)
      • InstanceName (Property)
      • Main (Method)
      • OnAfterOnlineChange (Method)
      • OnBeforeOnlineChange (Method)
      • SetBaseIdentification (Method)
    • CopyStr (Function)
    • IBaseInstance (Interface)
      • ComAddress (Property)
      • Init (Method)
      • InstanceName (Property)
      • Main (Method)
      • OnAfterOnlineChange (Method)
      • OnBeforeOnlineChange (Method)
    • IBaseInstance2 (Interface)
      • InitParametersDone (Property)
    • IEnvironmentExtender (Interface)
      • GetID (Property)
    • IModule (Interface)
      • ErrorHandling
        • ClearErrors (Method)
        • FirstErrorInstance (Property)
        • FirstErrorNumber (Property)
        • GetErrorMessage (Method)
        • GetFirstErrorMessage (Method)
        • GetLastErrorMessage (Method)
        • LastErrorInstance (Property)
        • LastErrorNumber (Property)
      • Identification
        • Environment (Property)
        • Handle (Property)
        • ModuleInfo (Property)
      • StandardCalls
        • CallPrioHighEnd (Method)
        • CallPrioHighStart (Method)
        • CallPrioLowEnd (Method)
        • CallPrioLowStart (Method)
        • CallPrioMediumEnd (Method)
        • CallPrioMediumStart (Method)
    • IModuleTree (Interface)
      • GetFirstChild (Method)
      • GetFirstToplevelInstance (Method)
      • GetParent (Method)
      • NextSibling (Method)
      • PrevSibling (Method)
    • MEnv (Struct)
    • Module (FunctionBlock)
      • ErrorHandling
        • ClearErrors (Method)
        • FirstErrorInstance (Property)
        • FirstErrorNumber (Property)
        • GetErrorMessage (Method)
        • GetFirstErrorMessage (Method)
        • GetLastErrorMessage (Method)
        • LastErrorInstance (Property)
        • LastErrorNumber (Property)
        • ReportError (Method)
      • Identification
        • Environment (Property)
        • Handle (Property)
        • ModuleInfo (Property)
        • SetIdentification (Method)
      • Init (Method)
      • Main (Method)
      • OnAfterOnlineChange (Method)
      • OnBeforeOnlineChange (Method)
      • StandardCalls
        • CallPrioHighEnd (Method)
        • CallPrioHighStart (Method)
        • CallPrioLowEnd (Method)
        • CallPrioLowStart (Method)
        • CallPrioMediumEnd (Method)
        • CallPrioMediumStart (Method)
    • ModuleHandle (Alias)
    • ModuleInfo (FunctionBlock)
      • ModuleType (Property)
    • ProxyInstance (FunctionBlock)
      • LocalComAddress (Property)
      • Main (Method)
      • SetProxyIdentification (Method)
    • TreeNavigation
      • AncestorRange (FunctionBlock)
        • First (Property)
        • Init (Method)
        • IsEmpty (Property)
        • PopFirst (Method)
      • DepthFirstRange (FunctionBlock)
        • First (Property)
        • Init (Method)
        • IsEmpty (Property)
        • PopFirst (Method)
      • GetAncestorRange (Function)
      • GetChildRange (Function)
      • GetDepthFirstRange (Function)
      • GetInstancePath (Function)
      • GetLastChild (Function)
      • GetLastInRange (Function)
      • GetLastSibling (Function)
      • GetNextModule (Function)
      • GetPrevModule (Function)
      • GetToplevelInstance (Function)
      • GetToplevelRange (Function)
      • IModuleRangeForward (Interface)
        • First (Property)
        • IsEmpty (Property)
        • PopFirst (Method)
      • SiblingRange (FunctionBlock)
        • First (Property)
        • Init (Method)
        • IsEmpty (Property)
        • PopFirst (Method)
  • AC_RMP_ReliableMessageProtocol
    • AC_RMP_FBCommunication
      • IRMPFBCommunication (Interface)
        • CyclicCall (Method)
        • InitializeCommunicationFBConnections (Method)
        • InitializeCommunicationParameters (Method)
        • InitializeReceiveBuffers (Method)
        • InitializeSendBuffers (Method)
        • ReceiveComAdress (Property)
        • ReceiveCounter (Property)
        • SendCounter (Property)
        • SendToComAdress (Property)
      • RMPVarData (Struct)
    • IRMPService (Interface)
      • IsMessageSent (Method)
      • LocalAppID (Property)
      • QueueSendMessage (Method)
      • Receive (Method)
    • IRmpService2 (Interface)
      • GetIsActionOngoing (Method)
      • SetIsActionOngoing (Method)
    • IRmpService3 (Interface)
      • GetComFBForComAddress (Method)
    • RMPBufferedMessage (Struct)
    • RMPConnection (FunctionBlock)
      • Activate (Method)
      • ActiveIndexInQueue (Property)
      • CheckConnectivity (Method)
      • Deactivate (Method)
      • IsActive (Property)
      • IsUp (Property)
    • RMPExchangeData (Struct)
    • RMPMessageBuffer (FunctionBlock)
      • AddMessage (Method)
      • ClearExpiredMessages (Method)
      • Delete (Method)
      • EnlargeExpirationTime (Method)
      • ExistsMessageWithHandle (Method)
      • GetMessage (Method)
      • GetMessageForReceiver (Method)
      • GetMessageToApplication (Method)
      • Lock (Method)
      • Unlock (Method)
    • RMPSendMessage (FunctionBlock)
      • CyclicAction (Method)
      • ResetAction (Method)
      • StartAction (Method)
    • RMPService (FunctionBlock)
      • Cyclic
        • CyclicCall (Method)
      • GetComFBForComAddress (Method)
      • GetIsActionOngoing (Method)
      • LocalAppID (Property)
      • Receive
        • Receive (Method)
      • Send
        • IsMessageSent (Method)
        • QueueSendMessage (Method)
      • SetIsActionOngoing (Method)
    • RMP_GVL (GVL)
    • RMP_GVL_CONST (GVL)
  • GenVisu
    • AC_Visu_Base (FunctionBlock)
      • Back (Method)
      • ChangeFrame (Method)
      • ClearHistory (Method)
      • Forward (Method)
      • GetModuleFrameIndex (Method)
      • Up (Method)
      • protected
        • GetAncestor (Method)
        • OnFrameIndexChanged (Method)
    • GVL_Visu (GVL)
    • GenVisu_Toplevel_Template
    • GetCurrentDisplayedModuleInstance (Function)
    • IModuleVisuClientListener (Interface)
      • ClientCreated (Method)
      • ClientDestroyed (Method)
    • OnClientCreatedOrDestroyed (Function)
    • OnClientCreatedOrDestroyed_2 (Function)
    • Toplevel_Vertical_Template
      • IP_Toplevel_Template (ImagePool)
  • GlobalTextList (GlobalTextList)
  • Library Information
    • GetLibVersion (Function)
    • GetLibVersionNumber (Function)
    • IsLibReleased (Function)
  • File and Project Information
  • Library Reference
    • AC_Persistence
      • Library Identification
      • Library Properties
      • Library Parameter
    • CAA Types Extern
      • Library Identification
      • Library Properties
    • CmpIecTask
      • Library Identification
      • Library Properties
    • CmpLog
      • Library Identification
      • Library Properties
    • Common Behaviour Model
      • Library Identification
      • Library Properties
    • Component Manager
      • Library Identification
      • Library Properties
    • IoStandard
      • Library Identification
      • Library Properties
    • Standard
      • Library Identification
      • Library Properties
    • SysCpuHandling
      • Library Identification
      • Library Properties
    • SysTypes2 Interfaces
      • Library Identification
      • Library Properties
    • VisuElem3DPath
      • Library Identification
      • Library Properties
      • Library Parameter
    • VisuElemCamDisplayer
      • Library Identification
      • Library Properties
      • Library Parameter
    • VisuElemMeter
      • Library Identification
      • Library Properties
    • VisuElemTextEditor
      • Library Identification
      • Library Properties
    • VisuElemTrace
      • Library Identification
      • Library Properties
    • VisuElemXYChart
      • Library Identification
      • Library Properties
    • VisuElems
      • Library Identification
      • Library Properties
    • VisuElemsAlarm
      • Library Identification
      • Library Properties
    • VisuElemsDateTime
      • Library Identification
      • Library Properties
    • VisuElemsSpecialControls
      • Library Identification
      • Library Properties
    • VisuElemsWinControls
      • Library Identification
      • Library Properties
    • VisuNativeControl
      • Library Identification
      • Library Properties
AC_ModuleBase
  • Docs »
  • AC_Module »
  • Module (FB) »
  • Identification

IdentificationΒΆ

  • Environment (Property)
  • Handle (Property)
  • ModuleInfo (Property)
  • SetIdentification (Method)