IACAlarmExtender2.Init2 (METH)ΒΆ
METHOD Init2
Initialization function to initialize the environment extender of the alarm generator. This function is called by code generated by the alarm generator.
- InOut:
Scope
Name
Type
Comment
Input
pModCallPOINTER TO ModuleCall
A pointer to a list of all module calls available under an application. The latter list is created by the alarm generator during an application composer generation.
uiModCallUINTThe number of module call defined in the list pointed to by pModCall.
pModEventsPOINTER TO ModuleEvent
A pointer to a list of all module events available under an application. The latter list is created by the alarm generator during an application composer generation.
uiModEventsUINTThe number of module events defined in the list pointed to by pModEvents.