Creating an image pool
In the device tree, select the Application object.
Click Project → Add Object → Image Pool.
The Add Image Pool dialog opens.
Type a name for the image pool (for example, "Images1") and click Add.
The image pool is added to the device tree.
Select the ImagePool object and click Project → Edit Object to open it.
Double-click the field in the ID column and assign an appropriate ID (for example, "
Icon1").Alternatively, you could also click Add Image File to add new images to the list.
Double-click the field in the File Name column. Click the
button.The Select Image dialog opens.
Click the
button and then select the image file.A thumbnail of the image file is displayed in the field of the column Image. The name of the file is displayed in the File name field.
The image file can be references only by the name Images1.Icon1.