Command: Install Test Script

Function: The command imports one or more test scripts from files into the selected test repository. In this way, you can take over test scripts which were exported with Export Test Script, for example from another test repository or from a sample package.

Call: Context menu of a test repository in the Test Manager view, Test Scripts tab

Requirement: Exactly one test repository is selected on the Test Scripts tab.

Procedure. Sequence
  1. The standard Open dialog is displayed. Only files of type Test Scripts (*.tsd.xml) are displayed.

  2. Select one or more files and click Open.

  3. The test scripts are copied to the test repository and are displayed on the Test Scripts tab.

The name and version of the test script are derived from the file name. Therefore, the file name must have the scheme <Name> (<Version>).tsd.xml, for example Examples.Counter_ApplicationTest (5.2.0.0).tsd.xml. Periods in the name define the folder structure in the test repository: The test script from the example is displayed as Counter_ApplicationTest in the Examples folder. Missing folders are created. Files created with Export Test Script already have this scheme.

Important

A test script is not installed if the test repository already contains a test script with the same name and the same version. Existing test scripts are not overwritten. However, a different version of the same test script is installed in addition.

If individual files cannot be installed, for example because of an invalid file name, then an error message with a list of these files and the cause is displayed after the process. All other test scripts are installed anyway.

You can also install test scripts from the command line.