Command: Unforce All Values

Keyboard shortcut: Alt+F7

Function: The command resets the forcing of all variables. The variables get their current values from the controller.

Call: Debug menu

Requirement: The application is in online mode.

The Release Force List command has the same functionality as this command with one difference: If the Remove Force List command cannot be executed for all forced values, then a message is not displayed.

Caution

Unusual changes to variable values in an application which is currently running on the controller can cause undesired behavior of the controlled plant.

Evaluate possible dangers before forcing variable values, and take the respective safety precautions. Depending on the controlled plant, this could result in damage to the plant or the workpieces, or injury or death of personnel.

Tip

The Unforce Values [all applications] command affects all application in the project and is not included in a menu by default.

For more information, see: Force Values and Forcing and Writing of Variables