Element: Connection Mark – Source/Sink
Symbol:
, 
Two connection marks with the same name represent a connection between the marked elements. This is helpful to make complex diagrams clearer.
For a valid connection, you need to connect a Connection Mark - Source element to the output of one element and a Connection Mark - Sink element to the input of another element. Both marks have to have the same name. In this case, uppercase and lowercase are not taken into consideration.
The default name for connection marks is
C-<number>. Here,<number>is a consecutive number starting at 1.You can rename the default name. You need to make sure that the source mark and the sink mark have the same name.
If you change the name of the source mark, then the sink name will be renamed automatically.
If you change the name of the sink mark, then the source name is retained.
Tip
You can use Connection Mark to convert the connection marks into a connecting line.