Error (ENUM)

TYPE Error :

SNMP Errors

InOut:

Name

Initial

Comment

NO_ERROR

0

No Error

NBS_ERROR

1

Error in NetBaseService (Connection error)

BUFFER_SIZE_EXCEEDED

2

Buffer size exceeded

TIME_OUT

3

Time out

UNKNOWN_USER

4

Unknown user (local): Check if the user has been created and the right user name has been set

UsmStatsUnsupportedSecLevels

100

Report: Security level not supported

UsmStatsNotInTimeWindows

101

Report: Request or response is not in time windows

UsmStatsUnknownUserNames

102

Report: User not found (remote)

UsmStatsUnknownEngineIDs

103

Report: Unknown engine Id

UsmStatsWrongDigests

104

Report: Authentification error

UsmStatsDecryptionErrors

105

Report: Decryption error

ALGORITHM_NOT_FOUND

201

USM: Unsupported algorithm

VERSION_NOT_SUPPORTED

400

Version is not Supportded

INIT_ERROR

401

Initialization Error

SEND_ERROR

402

Send Error

RECEIVE_ERROR

403

Receive Error

INVALID_OID

404

Invalid OID. The first subidentifier must be 0, 1 or 2. The second subidentifier must be between 0 and 39 if the first subidentifier is 0 or 1.

ENCRYPTION_NOT_SUPPORTED

405

The feature ‚encryption‘ is not supported by the device.

MAX_USER_EXCEEDED

406

The maximum number of users has been exceeded. You can edit the value in the parameterlist ‚Param‘.

INVALID_REFERENCE

407

Missing input value reference.