ReceiveSMS (FB)¶
FUNCTION_BLOCK ReceiveSMS EXTENDS CBM.ETrigTo
By use of this function block, the oldest short message from the device is displayed.
Just when the message is deleted, the next one is shown.
After starting this function block, it will try to allocate the modem.
When it is free a lock is set and therefore reserved for the currently function block.
After a reset (falling edge on “xExecute”) the lock is released.
- InOut:
Scope
Name
Type
Comment
Inherited from
Input
xExecuteBOOLRising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (xDone,xError) are present at the outputs for exactly one cycle.ETrigTo
udiTimeOutUDINTDefines the time (µs) after which an FB (e.g. requiring an external acknowledgement) aborts operation due to a timeout with error message.
ETrigTo
Output
xDoneBOOLTRUE: Action successfully completedETrigTo
xBusyBOOLTRUE: Function block activeETrigTo
xErrorBOOLTRUE: Error occurred, function block aborts actionFALSE: No errorETrigTo
Inout
ModemFBThe modem function block
Output
eErrorerror code
VisuResultThis output is needed for the visualization.
smsRecvThis structure includes the received short message