RecipeManCommands.GetRecipeValues (METH)¶
METHOD GetRecipeValues : DWORD
Returns the recipe values from the corresponding recipe
Example:
We have 50 recipe values. We want to create a table which shows 10 recipe values at the same time.
We define a string array strArr: ARRAY[0..9] OF STRING;
Corresponding to the iStartIndex we can get the recipe values from a specific area.
StartIndex:= 0; The values 0..9 are returned.
iStartIndex:= 20; The values 20..29 are returned.
In this example:
iStringLength:= 80;
iSize:= 10;
- InOut:
Scope
Name
Type
Comment
Return
GetRecipeValuesDWORDPossible last error values:
See ReturnValues (GVL) for a description of all possible errors.
Input
RecipeDefinitionNameSTRINGName of the recipe definition
RecipeNameSTRINGName of the recipe
pStringsPOINTER TO ARRAY [0..0] OF STRING
The strings where the recipe values should be stored
iSizeINTSize of the string array.
iStartIndexINTStart index. Can be used for a scrolling function (See example)
iStringLengthINTString length of the strings in the array