MQTTClient (FB)

FUNCTION_BLOCK MQTTClient EXTENDS CBML.LCon

Function block to connect with a MQTT broker

InOut:

Scope

Name

Type

Initial

Comment

Inherited from

Input

xEnable

BOOL

TRUE: Activates the defined operation FALSE: Aborts/resets the defined operation

LCon

Output

xDone

BOOL

TRUE: Ready condition reached

LCon

xBusy

BOOL

TRUE: Operation is running

LCon

xError

BOOL

TRUE: Error condition reached

LCon

Input

uiPort

UINT

Port of MQTT Broker Server

xUseTLS

BOOL

Obsolete, use itfTLSContext instead !

TRUE: Crypted Connection, FALSE: Uncrypted Connection

uiKeepAlive

UINT

5

Keep Alive Time in Seconds (optional)

pbWillMessage

POINTER TO BYTE

0

Pointer to the ‚Last Will‘ message (optional)

uiWillMessageSize

UINT

0

Size of ‚Last Will‘ message (optional)

xWillRetain

BOOL

TRUE: Saves the ‚Last Will‘ message on server. If Client subscribes later, then it receives the last stack message from server.

eWillQoS

MQTT_QOS

QoS Level of ‚Last Will‘ message

xCleanSession

BOOL

TRUE: Creates a new session, FALSE: Uses already existing session if available

wsUsername

WSTRING(255)

„“

User Name (optional)

wsPassword

WSTRING(1024)

„“

User Password (optional)

wsWillTopic

WSTRING(1024)

„“

Will Topic (optional)

sClientId

STRING(255)

‚‘

Client ID, if empty then new ID is generated, allowed are only these characters 0123456789abcdefghijklmnopqrstuvwxyzABCDEFGHIJKLMNOPQRSTUVWXYZ (optional)

tPingInterval

TIME

TIME#2s0ms

Interval time in seconds how often should be pinged, if Time<=0 then no pings

hCert

RTS_IEC_HANDLE

RTS_INVALID_HANDLE

Obsolete, use itfTLSContext instead !

Handle to the client certificate (optional)

itfTLSContext

NBS.ITLSContext

0

Encapsulates all the data neccecray to handle encrypted tcp connections

Static initialization, as shown in the following code snippet.

VAR
    commonName : STRING := 'MyRrasPi';
    ciCertInfo : NBS.CERT_INFO := (psInfo:=ADR(commonName), udiSize:=LEN(commonName));
    myTLSContext : NBS.TLSContext := (
        ePurpose:=NBS.PURPOSE.CLIENT_SIDE,
        sUseCaseName:='NBSTest',
        sTLSVersion:='1.3',
        ciCertInfo:=ciCertInfo,
        udiVerificationMode:=2
    );
END_VAR

itfAsyncProperty

NBS.IAsyncProperty

0

Runs the connect process in a own background task. Use this property if the connection setup takes longer than one task cycle (e.g. TLS connections)

udiTimeOut

UDINT

0

Defines the time (µs) after which the connection setup aborts with xError.

eCommunicationMode

COMMUNICATION_MODE

COMMUNICATION_MODE.TCP

Communication mode: TCP or WEB_SOCKET, default: TCP
  • COMMUNICATION_MODE.TCP: Configure the connection via the inputs: sHostname, uiPort and itfTLSContext

  • COMMUNICATION_MODE.WEB_SOCKET: Configure the connection via the inputs: sWebSocketUrl and itfTLSContext

Additional WebSocket options can be set via the method SetWebSocketOptions.

sWebSocketUrl

REFERENCE TO STRING(1024)

The uri of the websocket server. e.g ‚ws://localhost:8080‘ ws-URI = „ws:“ „//“ host [ „:“ port ] path [ „?“ query ] wss-URI = „wss:“ „//“ host [ „:“ port ] path [ „?“ query ]

The input is only relevant for eCommunicationMode = COMMUNICATION_MODE.WEB_SOCKET.

eMQTTVersion

MQTT_VERSION

MQTT_VERSION.V3_1_1

MQTT protocol version, default: 3.1.1

mQTTConnectProperties

REFERENCE TO MQTTConnectProperties

Connection properties for MQTT V5

mQTTWillProperties

REFERENCE TO MQTTWillProperties

Will properties for MQTT V5

Inout Const

sHostname

STRING(80)

Host name of Broker MQTT Server (is IPAddress)

Output

eMQTTError

MQTT_ERROR

MQTT Error Type

xConnectedToBroker

BOOL

FALSE

FALSE when there is no Connection to MQTT Broker Server, otherwise TRUE

eReaonCode

MQTT_REASON_CODE

Reason code of the last operation (MQTT V5 only)

mQTTConnackProperties

MQTTConnackProperties

Connection response properties (MQTT V5 only)

Properties:

Methods:

Structure: