GetDeviceError (FB)¶
FUNCTION_BLOCK GetDeviceError EXTENDS CBM.ETrigA
If IDevice.GetDeviceState returns DEVICE_STATE.ERROR this function block returns the associated device error code. The error codes are fieldbus specific and will be defined by the associated communication stack.
Bemerkung
This feature may not be supported by all fieldbus drivers.
eError
will return ERROR.NOT_SUPPORTED if not supported.
- InOut:
Scope
Name
Type
Comment
Inherited from
Input
xExecute
BOOL
Rising edge: Action startsFalling edge: Resets outputsIf a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values (xDone
,xError
,iError
) are present at the outputs for exactly one cycle.ETrigA
xAbort
BOOL
TRUE
: Action is stopped immediately and all outputs are reset to their initial values.ETrigA
Output
xDone
BOOL
TRUE
: Action successfully completedETrigA
xBusy
BOOL
TRUE
: Function block activeETrigA
xError
BOOL
TRUE
: Error occurred, function block aborts actionFALSE
: No errorETrigA
xAborted
BOOL
TRUE
: Action aborted by userETrigA
Input
itfNode
device node
Output
eError
operation error code
einDeviceError
device error code