Library Reference

This is a dictionary of all referenced libraries and their name spaces.

CAA FB Factory

Library Identification

Placeholder: CAA FB Factory
Default Resolution: CAA FB Factory, * (CAA Technical Workgroup)
Namespace: FBF

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CAA FB Factory

CAA Types Extern

Library Identification

Placeholder: CAA Types
Default Resolution: CAA Types Extern, * (CAA Technical Workgroup)
Namespace: CAA

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CAA Types

CmpCrypto

Library Identification

Placeholder: CmpCrypto
Default Resolution: CmpCrypto, * (System)
Namespace: CmpCrypto

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpCrypto

CmpErrors2 Interfaces

Library Identification

Name: CmpErrors2 Interfaces
Version: newest
Company: System
Namespace: CmpErrors

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpErrors2 Interfaces, * (System)

CmpX509Cert

Library Identification

Placeholder: CmpX509Cert
Default Resolution: CmpX509Cert, * (System)
Namespace: CmpX509Cert

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: CmpX509Cert

Common Behaviour Model

Library Identification

Placeholder: CBML
Default Resolution: Common Behaviour Model, * (3S - Smart Software Solutions GmbH)
Namespace: CBML

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: CBML

Component Manager

Library Identification

Placeholder: Component Manager
Default Resolution: Component Manager, * (System)
Namespace: Component_Manager

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Component Manager

Element Collections

Library Identification

Placeholder: ElementCollections
Default Resolution: Element Collections, * (3S - Smart Software Solutions GmbH)
Namespace: COL

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: ElementCollections

MQTT Client SL

Library Identification

Placeholder: MQTT_Client_SL
Default Resolution: MQTT Client SL, * (3S - Smart Software Solutions GmbH)
Namespace: MQTT

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: MQTT_Client_SL

Library Parameter

Parameter: G_UDIMAXPACKETSIZE = 6000
Parameter: G_UDIMAXPAYLOADSIZE = 4096
Parameter: G_UDIMAXPUBLISHERSANDSUBSCRIBERS = 20
Parameter: G_UDIMAXQUEUEDPACKETS = 1000
Parameter: G_UIMAXTOPICLEVEL = 10

Net Base Services

Library Identification

Placeholder: NetBaseSrv
Default Resolution: Net Base Services, * (3S - Smart Software Solutions GmbH)
Namespace: NBS

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: True

  • SystemLibrary: False

  • Key: NetBaseSrv

Standard

Library Identification

Placeholder: Standard
Default Resolution: Standard, * (System)
Namespace: Standard

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: Standard

StringUtils

Library Identification

Placeholder: StringUtils
Default Resolution: StringUtils, * (System)
Namespace: Stu

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: StringUtils

SysMem

Library Identification

Placeholder: SysMem
Default Resolution: SysMem, * (System)
Namespace: SysMem

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysMem

SysTypes2 Interfaces

Library Identification

Name: SysTypes2 Interfaces
Version: newest
Company: System
Namespace: SysTypes

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: False

  • Key: SysTypes2 Interfaces, * (System)

VisuElem3DPath

Library Identification

Placeholder: System_VisuElem3DPath
Default Resolution: VisuElem3DPath, 3.5.15.0 (System)
Namespace: VisuElem3DPath

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElem3DPath

Library Parameter

Parameter: GC_POINTS_PER_POLYGON = 100

VisuElemCamDisplayer

Library Identification

Placeholder: System_VisuElemCamDisplayer
Default Resolution: VisuElemCamDisplayer, 3.5.15.0 (System)
Namespace: VisuElemCamDisplayer

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemCamDisplayer

Library Parameter

Parameter: GC_POINTS_PER_CAM = 100

VisuElemMeter

Library Identification

Placeholder: System_VisuElemMeter
Default Resolution: VisuElemMeter, 3.5.15.0 (System)
Namespace: VisuElemMeter

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemMeter

VisuElemTextEditor

Library Identification

Placeholder: System_VisuElemTextEditor
Default Resolution: VisuElemTextEditor, 3.5.15.0 (System)
Namespace: VisuElemTextEditor

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemTextEditor

VisuElemTrace

Library Identification

Placeholder: System_VisuElemTrace
Default Resolution: VisuElemTrace, 3.5.15.20 (System)
Namespace: VisuElemTrace

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemTrace

VisuElemXYChart

Library Identification

Placeholder: System_VisuElemXYChart
Default Resolution: VisuElemXYChart, 3.5.15.0 (System)
Namespace: VisuElemXYChart

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemXYChart

VisuElems

Library Identification

Placeholder: System_VisuElems
Default Resolution: VisuElems, 3.5.15.20 (System)
Namespace: VisuElems

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElems

VisuElemsAlarm

Library Identification

Placeholder: System_VisuElemsAlarm
Default Resolution: VisuElemsAlarm, 3.5.15.0 (System)
Namespace: VisuElemsAlarm

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsAlarm

VisuElemsDateTime

Library Identification

Placeholder: System_VisuElemsDateTime
Default Resolution: VisuElemsDateTime, 3.5.15.10 (System)
Namespace: VisuElemsDateTime

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsDateTime

VisuElemsSpecialControls

Library Identification

Placeholder: System_VisuElemsSpecialControls
Default Resolution: VisuElemsSpecialControls, 3.5.15.0 (System)
Namespace: VisuElemsSpecialControls

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsSpecialControls

VisuElemsWinControls

Library Identification

Placeholder: System_VisuElemsWinControls
Default Resolution: VisuElemsWinControls, 3.5.15.20 (System)
Namespace: VisuElemsWinControls

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuElemsWinControls

VisuInputs

Library Identification

Placeholder: system_visuinputs
Default Resolution: VisuInputs, 3.5.15.0 (System)
Namespace: visuinputs

Library Properties

  • LinkAllContent: False

  • Optional: False

  • PublishSymbolsInContainer: True

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: system_visuinputs

VisuNativeControl

Library Identification

Placeholder: System_VisuNativeControl
Default Resolution: VisuNativeControl, 3.5.15.0 (System)
Namespace: VisuNativeControl

Library Properties

  • LinkAllContent: False

  • Optional: False

  • QualifiedOnly: False

  • SystemLibrary: True

  • Key: System_VisuNativeControl